Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 14, 2017, 07:57 PM
  • G 0185_G 0184_4142017_130603.mp4

Date
04/14/2017
W/O
0634747
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z01180
PipeID
P01089
Time
12:57 PM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7385
Sewer Name
G JOINT OUTFALL G - UNIT 8
City
LYNWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
13
Purpose
Routine Assessment
Project
20170414DF_JOINT_OUTFALL_G_UNIT_8
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Upstream MH
G 0184
Downstream MH
G 0185
Dir. of Survey
Upstream
Length Surveyed
73.2 ft.
Total Length
73.2 ft.
Structural Index
3
Structural Quick
5442
Structural Rating
40
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
40
Pipe schematic from manhole G 0184 to G 0185
MH: G 0184MH: G 0185upstream0 ft. AMH - Upstream Manhole, Survey Ends - 1:42 PM0.4 ft. SSS - Surface Spalling, from 12 to 12 o'clock, within 8 inches of joint: YES, Finish11.2 ft. MGP - General Photograph - BROKEN11.7 ft. B - Broken, from 12 to 12 o'clock, within 8 inches of joint: YES18 ft. CC - Crack Circumferential, from 12 to 12 o'clock, within 8 inches of joint: YES30 ft. B - Broken, from 12 to 12 o'clock, within 8 inches of joint: YES34 ft. B - Broken, from 04 to 07 o'clock, within 8 inches of joint: YES35.8 ft. CL - Crack Longitudinal, at 05 o'clock, within 8 inches of joint: YES38.9 ft. CC - Crack Circumferential, from 07 to 05 o'clock, within 8 inches of joint: YES46.9 ft. B - Broken, from 05 to 06 o'clock, within 8 inches of joint: YES51.5 ft. B - Broken, from 12 to 12 o'clock, within 8 inches of joint: YES52.7 ft. CS - Crack Spiral, from 04 to 11 o'clock, within 8 inches of joint: YES61.4 ft. CS - Crack Spiral, from 06 to 08 o'clock, within 8 inches of joint: YES62.2 ft. CS - Crack Spiral, from 07 to 08 o'clock, within 8 inches of joint: YES70.6 ft. B - Broken, from 01 to 02 o'clock, within 8 inches of joint: YES71.2 ft. SSS - Surface Spalling, from 12 to 12 o'clock, within 8 inches of joint: YES, Start73.1 ft. MWM - Water Mark, 0 %of cross sectional area - AIRLINE73.1 ft. MWL - Water Level, 0 %of cross sectional area - AIRLINE73.2 ft. AMH - Downstream Manhole, Survey Begins - 1:01 PM

Observation photos (14)

  • Surface Spalling, from 12 to 12 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 12 to 12 o'clock, within 8 inches of joint: YES, Start

  • Broken, from 01 to 02 o'clock, within 8 inches of joint: YES

    2.6 ft. - Broken, from 01 to 02 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 07 to 08 o'clock, within 8 inches of joint: YES

    11 ft. - Crack Spiral, from 07 to 08 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 06 to 08 o'clock, within 8 inches of joint: YES

    11.8 ft. - Crack Spiral, from 06 to 08 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 04 to 11 o'clock, within 8 inches of joint: YES

    20.5 ft. - Crack Spiral, from 04 to 11 o'clock, within 8 inches of joint: YES

  • Broken, from 12 to 12 o'clock, within 8 inches of joint: YES

    21.7 ft. - Broken, from 12 to 12 o'clock, within 8 inches of joint: YES

  • Broken, from 05 to 06 o'clock, within 8 inches of joint: YES

    26.3 ft. - Broken, from 05 to 06 o'clock, within 8 inches of joint: YES

  • Crack Circumferential, from 07 to 05 o'clock, within 8 inches of joint: YES

    34.3 ft. - Crack Circumferential, from 07 to 05 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 05 o'clock, within 8 inches of joint: YES

    37.4 ft. - Crack Longitudinal, at 05 o'clock, within 8 inches of joint: YES

  • Broken, from 04 to 07 o'clock, within 8 inches of joint: YES

    39.2 ft. - Broken, from 04 to 07 o'clock, within 8 inches of joint: YES

  • Broken, from 12 to 12 o'clock, within 8 inches of joint: YES

    43.2 ft. - Broken, from 12 to 12 o'clock, within 8 inches of joint: YES

  • Crack Circumferential, from 12 to 12 o'clock, within 8 inches of joint: YES

    55.2 ft. - Crack Circumferential, from 12 to 12 o'clock, within 8 inches of joint: YES

  • Broken, from 12 to 12 o'clock, within 8 inches of joint: YES

    61.5 ft. - Broken, from 12 to 12 o'clock, within 8 inches of joint: YES

  • General Photograph - BROKEN

    62 ft. - General Photograph - BROKEN

Observations (19)

DistanceCodeObservation
2.6B
72.8SSS
37.4CL
0.1MWMAIRLINE
61.5B
2SSS
0AMH1:01 PM
43.2B
73.2AMH1:42 PM
39.2B
55.2CC
0.1MWLAIRLINE
26.3B
11CS
21.7B
20.5CS
62MGPBROKEN
11.8CS
34.3CC

Properties (3)

custom_field_two
1
customer
LACSD
datetime
2017-04-14T12:57:39-07:00