Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 31, 2017, 10:09 AM
  • 15 0360_15 0359_3312017_031812.mp4

Date
03/31/2017
W/O
0619136
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00598
PipeID
P12286
Time
3:09 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0480
Sewer Name
15 BALDWIN PARK TRUNK
City
BALDWIN PARK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
24
Purpose
Routine Assessment
Project
20170331MDM_BALDWIN_PARK_TRUNK
Material
NRCP
Shape
Circular
Height
18 in.
Upstream MH
15 0360
Downstream MH
15 0359
Dir. of Survey
Downstream
Length Surveyed
173.8 ft.
Total Length
173.8 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
4
O&M Quick
5142
O&M Rating
13
Overall Index
4
Overall Quick
Overall Rating
19
Pipe schematic from manhole 15 0360 to 15 0359
MH: 15 0360MH: 15 0359downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 3:15AM2 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2 ft. MGO - General Observation - MAG COAT 40% START 9:00 TO 3:0015.8 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG23.4 ft. MWM - Water Mark, 80 %of cross sectional area23.4 ft. MWL - Water Level, 20 %of cross sectional area40.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped44.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped64.7 ft. MWL - Water Level, 10 %of cross sectional area64.7 ft. MWM - Water Mark, 50 %of cross sectional area94.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped114.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped138.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped143 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped173.4 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. OPEN173.4 ft. MGO - General Observation - MAG COAT 40% FINISH173.4 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG173.8 ft. AMH - Downstream Manhole, Survey Ends - 3:30AM

Observation photos (4)

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • General Observation - MAG COAT 40% START 9:00 TO 3:00

    2 ft. - General Observation - MAG COAT 40% START 9:00 TO 3:00

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

    15.8 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Water Mark, 80 %of cross sectional area

    23.4 ft. - Water Mark, 80 %of cross sectional area

Observations (20)

DistanceCodeObservation
64.7MWL
173.8AMH3:30AM
15.8SAVSEVERE AGG
173.4MGOConn. @ Mh, 9 O' Clock. OPEN
114.1TFCCapped
23.4MWM
173.4MGOMAG COAT 40% FINISH
44.7TFCCapped
23.4MWL
64.7MWM
173.4SAVSEVERE AGG
94.1TFCCapped
0MWM
143TFCCapped
40.7TFCCapped
2SAVSEVERE AGG
0MWL
2MGOMAG COAT 40% START 9:00 TO 3:00
0AMH3:15AM
138.3TFCCapped

Properties (4)

custom_field_three
SEVERE AGG VISIBLE
custom_field_two
4
customer
LACSD
datetime
2017-03-31T03:09:33-07:00