Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 23, 2017, 08:52 AM
  • H 0072_H 0071_3232017_035223.mp4

Date
03/23/2017
W/O
0619086
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00164
PipeID
P10524
Time
1:52 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0475
Sewer Name
H JOINT OUTFALL H - UNIT 1E
City
SOUTH GATE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
11
Purpose
Routine Assessment
Project
20170322MDM_JOINT_OUTFALL_H_UNIT_1E
Material
Reinforced Concrete Pipe
Shape
Circular
Height
35.5 in.
Upstream MH
H 0072
Downstream MH
H 0071
Dir. of Survey
Downstream
Length Surveyed
62.7 ft.
Total Length
62.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
5
O&M Quick
5100
O&M Rating
5
Overall Index
5
Overall Quick
Overall Rating
5
Pipe schematic from manhole H 0072 to H 0071
MH: H 0072MH: H 0071downstream0 ft. MWM - Water Mark, 80 %of cross sectional area0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. OPEN0 ft. AMH - Upstream Manhole, Survey Begins - 3:50AM2 ft. MGO - General Observation - LOOSE JOINT SEALER8 ft. MGO - General Observation - RCP-PVC62.7 ft. AMH - Downstream Manhole, Survey Ends - 4:00AM

Observation photos (2)

  • General Observation - LOOSE JOINT SEALER

    2 ft. - General Observation - LOOSE JOINT SEALER

  • General Observation - RCP-PVC

    8 ft. - General Observation - RCP-PVC

Observations (7)

DistanceCodeObservation
0MWM
2MGOLOOSE JOINT SEALER
8MGORCP-PVC
62.7AMH4:00AM
0MWL
0MGOConn. @ Mh, 9 O' Clock. OPEN
0AMH3:50AM

Properties (5)

additional_info
PVC LINER
custom_field_three
PVC LINER
custom_field_two
4
customer
LACSD
datetime
2017-03-23T01:52:28-07:00