Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 6, 2017, 08:26 PM
  • 15 1132_15 1131_362017_123011.mp4

Date
03/06/2017
W/O
0624554
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00908
PipeID
P13037
Time
12:26 PM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7353
Sewer Name
15 CONTINENTAL AVENUE RELIEF TRUNK
City
SOUTH EL MONTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
28
Purpose
Routine Assessment
Project
20170306DF_CONTINENTAL_AVE_REL_TR
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
15 1132
Downstream MH
15 1131
Dir. of Survey
Downstream
Length Surveyed
304.2 ft.
Total Length
304.2 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 15 1132 to 15 1131
MH: 15 1132MH: 15 1131downstream0 ft. AMH - Upstream Manhole, Survey Begins - 12:30 PM0.1 ft. MWM - Water Mark, 30 %of cross sectional area0.1 ft. MWL - Water Level, 25 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start302.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish302.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish304.2 ft. AMH - Downstream Manhole, Survey Ends - 12:47 PM

Observation photos (1)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
2SSS
2CM
0.1MWM
302.4SSS
302.4CM
0AMH12:30 PM
304.2AMH12:47 PM
0.1MWL

Properties (3)

customer
LACSD
datetime
2017-03-06T12:26:06-08:00
year_laid
19910913