Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 22, 2017, 09:16 AM
  • 08 0002_08 0683_2222017_045652.mp4

Date
02/22/2017
W/O
0613373
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00016
PipeID
P24998
Time
1:16 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0452
Sewer Name
08 MAIN STREET TRUNK
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
10
Purpose
Capital Improvement Program Assesment
Project
20170217MDM_MAIN_STREET_TRUNK
Material
RCP-CTL
Shape
Circular
Height
33 in.
Upstream MH
08 0002
Downstream MH
08 0683
Dir. of Survey
Downstream
Length Surveyed
268.6 ft.
Total Length
268.6 ft.
Structural Index
5
Structural Quick
5A41
Structural Rating
59
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
5
Overall Quick
Overall Rating
63
Pipe schematic from manhole 08 0002 to 08 0683
MH: 08 0002MH: 08 0683downstream0 ft. AMH - Upstream Manhole, Survey Begins - 4:30AM0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. MWM - Water Mark, 60 %of cross sectional area0 ft. MWL - Water Level, 50 %of cross sectional area2 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2 ft. MGO - General Observation - MISSING TILES 70% START10.8 ft. SRV - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: NO - CIRCUM14.2 ft. MGO - General Observation - MISSING TILES 100%14.2 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES - CIRCUM REBAR17.7 ft. SRV - Surface Reinforcement Visible, from 12 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR24 ft. MGO - General Observation - 2 ROWS TILES29.3 ft. SRV - Surface Reinforcement Visible, from 12 to 03 o'clock, within 8 inches of joint: YES, Finish - CIRCUM REBAR29.3 ft. SRC - Surface Reinforcement Corroded, from 11 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR LONG REBAE30 ft. SRC - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: YES - LONG REBAR39.2 ft. MGO - General Observation - 2 ROWS TILES60.6 ft. MGO - General Observation - 20% MISSING TILES START60.6 ft. SRC - Surface Reinforcement Corroded, from 11 to 03 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REBAR73.2 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR92.5 ft. SRC - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES92.5 ft. MGO - General Observation - MISSING TILES 70% START98.5 ft. MGO - General Observation - 2 ROWS TILES114.7 ft. SRC - Surface Reinforcement Corroded, from 11 to 02 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR120 ft. MGO - General Observation - MISSING TILES 50% START127 ft. SRC - Surface Reinforcement Corroded, from 11 to 02 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR140.1 ft. SRC - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM LONG REBAR151.3 ft. MGO - General Observation - MISSING TILES 90% START173.2 ft. SRC - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR213.2 ft. MGO - General Observation - 1 ROW TILES236.5 ft. MGO - General Observation - 2 ROWS TILE236.6 ft. MGO - General Observation - DEBRI ON CABLE268.3 ft. MGO - General Observation - MISSING TILES 90% FINISH268.3 ft. SRC - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REBAR268.3 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG268.6 ft. AMH - Downstream Manhole, Survey Ends - 5:15AM

Observation photos (17)

  • Water Mark, 60 %of cross sectional area

    0 ft. - Water Mark, 60 %of cross sectional area

  • General Observation - MISSING TILES 70% START

    2 ft. - General Observation - MISSING TILES 70% START

  • Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: NO - CIRCUM

    10.8 ft. - Surface Reinforcement Visible, from 12 to 01 o'clock, within 8 inches of joint: NO - CIRCUM

  • General Observation - MISSING TILES 100%

    14.2 ft. - General Observation - MISSING TILES 100%

  • Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

    14.2 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

  • Surface Reinforcement Visible, from 12 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

    17.7 ft. - Surface Reinforcement Visible, from 12 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

  • Surface Reinforcement Corroded, from 11 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR  LONG REBAE

    29.3 ft. - Surface Reinforcement Corroded, from 11 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR LONG REBAE

  • Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: YES - LONG REBAR

    30 ft. - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: YES - LONG REBAR

  • General Observation - 20% MISSING TILES START

    60.6 ft. - General Observation - 20% MISSING TILES START

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR

    73.2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR

  • Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES

    92.5 ft. - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES

  • Surface Reinforcement Corroded, from 11 to 02 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR

    114.7 ft. - Surface Reinforcement Corroded, from 11 to 02 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR

  • General Observation - MISSING TILES 50% START

    120 ft. - General Observation - MISSING TILES 50% START

  • Surface Reinforcement Corroded, from 11 to 02 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR

    127 ft. - Surface Reinforcement Corroded, from 11 to 02 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR

  • Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM LONG REBAR

    140.1 ft. - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM LONG REBAR

  • Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    173.2 ft. - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • General Observation - DEBRI ON CABLE

    236.6 ft. - General Observation - DEBRI ON CABLE

Observations (35)

DistanceCodeObservation
268.3MGOMISSING TILES 90% FINISH
92.5SRC
236.5MGO2 ROWS TILE
213.2MGO1 ROW TILES
114.7SRCLONG CIRCUM REBAR
29.3SRVCIRCUM REBAR
73.2SRCLONG CIRCUM REBAR
24MGO2 ROWS TILES
127SRCLONG CIRCUM REBAR
268.3SRCLONG CIRCUM REBAR
140.1SRCCIRCUM LONG REBAR
120MGOMISSING TILES 50% START
92.5MGOMISSING TILES 70% START
0AMH4:30AM
0MGOConn. @ Mh, 9 O' Clock. Active
10.8SRVCIRCUM
30SRCLONG REBAR
14.2MGOMISSING TILES 100%
98.5MGO2 ROWS TILES
0MGOConn. @ Mh, 3 O' Clock. Active
151.3MGOMISSING TILES 90% START
2SAMSEVERE AGG
236.6MGODEBRI ON CABLE
29.3SRCCIRCUM REBAR LONG REBAE
268.6AMH5:15AM
60.6MGO20% MISSING TILES START
2MGOMISSING TILES 70% START
0MWM
14.2SRVCIRCUM REBAR
173.2SRCCIRCUM REBAR
39.2MGO2 ROWS TILES
17.7SRVCIRCUM REBAR
268.3SAMSEVERE AGG
0MWL
60.6SRCLONG CIRCUM REBAR

Properties (4)

custom_field_three
CORRODED LONG CIRCUM REBAR
custom_field_two
2
customer
LACSD
datetime
2017-02-22T01:16:10-08:00