Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 22, 2017, 09:11 AM
  • 08 0004_08 0003_2222017_024300.mp4

Date
02/22/2017
W/O
0613373
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00016
PipeID
P00004
Time
1:11 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0452
Sewer Name
08 MAIN STREET TRUNK
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
10
Purpose
Capital Improvement Program Assesment
Project
20170217MDM_MAIN_STREET_TRUNK
Material
RCP-CTL
Shape
Circular
Height
33 in.
Upstream MH
08 0004
Downstream MH
08 0003
Dir. of Survey
Downstream
Length Surveyed
276.3 ft.
Total Length
276.3 ft.
Structural Index
5
Structural Quick
5841
Structural Rating
44
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
5
Overall Quick
Overall Rating
48
Pipe schematic from manhole 08 0004 to 08 0003
MH: 08 0004MH: 08 0003downstream0 ft. AMH - Upstream Manhole, Survey Begins - 2:15AM0 ft. MWM - Water Mark, 60 %of cross sectional area0 ft. MWL - Water Level, 40 %of cross sectional area2 ft. MGO - General Observation - MISSING TILES 100% START2 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG5.8 ft. SRV - Surface Reinforcement Visible, from 02 to 03 o'clock, within 8 inches of joint: YES - CIRCUM REBAR15.1 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR17.3 ft. SRC - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR20.5 ft. MGO - General Observation - 2 VROWS TILE34.7 ft. SRV - Surface Reinforcement Visible, from 09 to 10 o'clock, within 8 inches of joint: NO - CIRCUM40 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR40 ft. SRC - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES, Finish - CIRCUM REBAR87.3 ft. MGP - General Photograph87.3 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR89.1 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR227.9 ft. MGO - General Observation - 1 ROW TILES260.4 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR276 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. OPEN 100% GREASE276 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG276 ft. SRC - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REBAR276.3 ft. AMH - Downstream Manhole, Survey Ends - 2:50AM

Observation photos (10)

  • General Observation - MISSING TILES 100% START

    2 ft. - General Observation - MISSING TILES 100% START

  • Surface Reinforcement Visible, from 02 to 03 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

    5.8 ft. - Surface Reinforcement Visible, from 02 to 03 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

    15.1 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES - CIRCUM REBAR

  • Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

    17.3 ft. - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

  • General Observation - 2 VROWS TILE

    20.5 ft. - General Observation - 2 VROWS TILE

  • Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES, Finish - CIRCUM REBAR

    40 ft. - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES, Finish - CIRCUM REBAR

  • General Photograph

    87.3 ft. - General Photograph

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    87.3 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR

    89.1 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - LONG CIRCUM REBAR

  • Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR

    260.4 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR

Observations (21)

DistanceCodeObservation
40SRCLONG CIRCUM REBAR
87.3MGP
34.7SRVCIRCUM
17.3SRCCIRCUM REBAR
227.9MGO1 ROW TILES
89.1SRCLONG CIRCUM REBAR
0AMH2:15AM
40SRCCIRCUM REBAR
15.1SRCCIRCUM REBAR
260.4SRCLONG CIRCUM REBAR
276.3AMH2:50AM
0MWM
2MGOMISSING TILES 100% START
276MGOConn. @ Mh, 9 O' Clock. OPEN 100% GREASE
5.8SRVCIRCUM REBAR
87.3SRCCIRCUM REBAR
276SAMSEVERE AGG
20.5MGO2 VROWS TILE
0MWL
2SAMSEVERE AGG
276SRCLONG CIRCUM REBAR

Properties (4)

custom_field_three
CORRODED LONG CIRCUM REBAR
custom_field_two
2
customer
LACSD
datetime
2017-02-22T01:11:49-08:00