Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 21, 2017, 09:07 AM
  • 08 0007_08 0006_2212017_030624.mp4

Date
02/21/2017
W/O
0613622
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00016
PipeID
P00007
Time
1:07 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0451
Sewer Name
08 MAIN STREET TRUNK
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
07
Purpose
Capital Improvement Program Assesment
Project
20170217MDM_MAIN_STREET_TRUNK
Material
RCP-CTL
Shape
Circular
Height
33 in.
Upstream MH
08 0007
Downstream MH
08 0006
Dir. of Survey
Downstream
Length Surveyed
14.7 ft.
Total Length
14.7 ft.
Structural Index
5
Structural Quick
5341
Structural Rating
19
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
5
Overall Quick
Overall Rating
19
Pipe schematic from manhole 08 0007 to 08 0006
MH: 08 0007MH: 08 0006downstream0 ft. AMH - Upstream Manhole, Survey Begins - 2:50AM0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Capped2 ft. MGO - General Observation - MISSING TILES 70%2 ft. SAM - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS OF MISSING TILES3.1 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR4.5 ft. SRC - Surface Reinforcement Corroded, from 12 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR MISSING5.5 ft. SRC - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: YES - LONG REBAR6.2 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REBAR14.3 ft. SAM - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG AREAS OF MISSING TILES14.3 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active14.7 ft. AMH - Downstream Manhole, Survey Ends - 3:00AM

Observation photos (4)

  • General Observation - MISSING TILES 70%

    2 ft. - General Observation - MISSING TILES 70%

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

    3.1 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

  • Surface Reinforcement Corroded, from 12 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR MISSING

    4.5 ft. - Surface Reinforcement Corroded, from 12 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR MISSING

  • Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: YES - LONG REBAR

    5.5 ft. - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: YES - LONG REBAR

Observations (12)

DistanceCodeObservation
2MGOMISSING TILES 70%
6.2SRCLONG CIRCUM REBAR
0AMH2:50AM
4.5SRCCIRCUM REBAR MISSING
14.3SAMSEVERE AGG AREAS OF MISSING TILES
14.7AMH3:00AM
2SAMSEVERE AGG AREAS OF MISSING TILES
3.1SRCCIRCUM REBAR
14.3MGOConn. @ Mh, 3 O' Clock. Active
0MGOConn. @ Mh, 3 O' Clock. Active
5.5SRCLONG REBAR
0MGOConn. @ Mh, 9 O' Clock. Capped

Properties (4)

custom_field_three
CORRODED MISSING REBAR
custom_field_two
1
customer
LACSD