Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 13, 2017, 09:49 PM
  • B 0234_B 0215_2132017_141446.mp4

Date
02/13/2017
W/O
0623303
Weather
Dry
Operator/Surveyor
MIRANDA
Sewer ID
Z00077
PipeID
P08702
Time
1:49 PM
Certificate
U-1014-06022542
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7332
Sewer Name
B JOINT OUTFALL B - UNIT 1E
City
MONTEBELLO
Loc. details
Sidewalk
Location Code
F
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
11
Purpose
Routine Assessment
Project
20170213AM_JOINT_OUTFALL_B_UNIT_1E
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Upstream MH
B 0234
Downstream MH
B 0215
Dir. of Survey
Downstream
Length Surveyed
156.2 ft.
Total Length
156.2 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole B 0234 to B 0215
MH: B 0234MH: B 0215downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:13 PM0 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start72.1 ft. MWL - Water Level, 25 %of cross sectional area102.9 ft. MWL - Water Level, 35 %of cross sectional area109.7 ft. MWL - Water Level, 40 %of cross sectional area121.5 ft. MWL - Water Level, 50 %of cross sectional area155.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish155.8 ft. MGO - General Observation - DEBRIS THROUGHOUT THE REACH155.8 ft. MGO - General Observation - ACTIVE CONN. INSIDE THE MH. @ 09 O'CLOCK155.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish156.2 ft. AMH - Downstream Manhole, Survey Ends - 2:30 PM

Observation photos (8)

  • Water Mark, 50 %of cross sectional area

    0 ft. - Water Mark, 50 %of cross sectional area

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Water Level, 25 %of cross sectional area

    72.1 ft. - Water Level, 25 %of cross sectional area

  • Water Level, 35 %of cross sectional area

    102.9 ft. - Water Level, 35 %of cross sectional area

  • Water Level, 40 %of cross sectional area

    109.7 ft. - Water Level, 40 %of cross sectional area

  • Water Level, 50 %of cross sectional area

    121.5 ft. - Water Level, 50 %of cross sectional area

  • Downstream Manhole, Survey Ends - 2:30 PM

    156.2 ft. - Downstream Manhole, Survey Ends - 2:30 PM

Observations (14)

DistanceCodeObservation
0MWL
155.8SSS
72.1MWL
0AMH2:13 PM
155.8MGODEBRIS THROUGHOUT THE REACH
2SSS
109.7MWL
0MWM
155.8MGOACTIVE CONN. INSIDE THE MH. @ 09 O'CLOCK
155.8SAV
156.2AMH2:30 PM
121.5MWL
2SAV
102.9MWL

Properties (3)

custom_field_two
3
customer
LACSD
datetime
2017-02-13T13:49:36-08:00