Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 13, 2017, 07:17 PM
  • B 0237_B 0236_2132017_112015.mp4

Date
02/13/2017
W/O
0623303
Weather
Dry
Operator/Surveyor
MIRANDA
Sewer ID
Z00077
PipeID
P08705
Time
11:17 AM
Certificate
U-1014-06022542
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7331
Sewer Name
B JOINT OUTFALL B - UNIT 1E
City
MONTEBELLO
Loc. details
Other
Location Code
Z
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
11
Purpose
Routine Assessment
Project
20170213AM_JOINT_OUTFALL_B_UNIT_1E
Material
NRCP
Shape
Circular
Height
21 in.
Upstream MH
B 0237
Downstream MH
B 0236
Dir. of Survey
Downstream
Length Surveyed
17.1 ft.
Total Length
17.1 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole B 0237 to B 0236
MH: B 0237MH: B 0236downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 11:19 AM0 ft. MGO - General Observation - UNKNOWN CONN. INSIDE THE MH. @ 09 O'CLOCK2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start5.8 ft. RPZ - Repair Other, within 8 inches of joint: YES, Start - VCP CAP8.1 ft. MGP - General Photograph - VCP CAP12.5 ft. RPZ - Repair Other, within 8 inches of joint: YES, Finish - VCP CAP16.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish16.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish16.5 ft. MWL - Water Level, 100 %of cross sectional area17 ft. LD - Alignment Down, 45 %17.1 ft. MSA - Survey Abandoned - VIEW OF THE DOWNLEG PIPE OF THE U/S SIPHON

Observation photos (8)

  • Upstream Manhole, Survey Begins - 11:19 AM

    0 ft. - Upstream Manhole, Survey Begins - 11:19 AM

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Repair Other, within 8 inches of joint: YES, Start - VCP CAP

    5.8 ft. - Repair Other, within 8 inches of joint: YES, Start - VCP CAP

  • General Photograph - VCP CAP

    8.1 ft. - General Photograph - VCP CAP

  • Repair Other, within 8 inches of joint: YES, Finish - VCP CAP

    12.5 ft. - Repair Other, within 8 inches of joint: YES, Finish - VCP CAP

  • Water Level, 100 %of cross sectional area

    16.5 ft. - Water Level, 100 %of cross sectional area

  • Survey Abandoned - VIEW OF THE DOWNLEG PIPE OF THE U/S SIPHON

    17.1 ft. - Survey Abandoned - VIEW OF THE DOWNLEG PIPE OF THE U/S SIPHON

Observations (13)

DistanceCodeObservation
0MWL
5.8RPZVCP CAP
17.1MSAVIEW OF THE DOWNLEG PIPE OF THE U/S SIPHON
12.5RPZVCP CAP
0AMH11:19 AM
16.4SSS
2SSS
2SAV
8.1MGPVCP CAP
16.5MWL
17LD
0MGOUNKNOWN CONN. INSIDE THE MH. @ 09 O'CLOCK
16.4SAV

Properties (4)

additional_info
VIEW OF THE DOWNLEG PIPE OF THE U/S SIPHON
custom_field_two
3
customer
LACSD
datetime
2017-02-13T11:17:01-08:00