21 1074_21 1073_282017_105825.mp4
0 ft. - Downstream Manhole, Survey Begins - 10:55 AM
0 ft. - Water Level, 5 %of cross sectional area
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
390.4 ft. - General Photograph - SEVERE EXPOSED AGGREGATE
400.6 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES, Start
411 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES, Finish
414 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish
414.8 ft. - General Observation - BRICK BULKHEAD INSIDE THE MH. @ 09 O'CLOCK
414.8 ft. - General Observation - POSSIBLE CAPPED OFF CONN. INSIDE THE MH. @ 12 O'CLOCK
415 ft. - Upstream Manhole, Survey Ends - 11:31 AM
| Distance | Code | Observation |
|---|---|---|
| 414 | SAV | — |
| 2 | SSS | — |
| 0 | AMH | 10:55 AM |
| 0 | MWL | — |
| 411 | SRV | — |
| 414.8 | MGO | BRICK BULKHEAD INSIDE THE MH. @ 09 O'CLOCK |
| 2 | SAV | — |
| 414.8 | MGO | POSSIBLE CAPPED OFF CONN. INSIDE THE MH. @ 12 O'CLOCK |
| 390.4 | MGP | SEVERE EXPOSED AGGREGATE |
| 414 | SSS | — |
| 415 | AMH | 11:31 AM |
| 400.6 | SRV | — |