2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM & LONG REBAR CORRODED,BROKEN,MISSING
2 ft. - General Observation - MISSING TILES 90% START 10;00 TO 2:00
2 ft. - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
27.2 ft. - Deposits Settled Other, 50 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES - TILES & DEBRIE
40.3 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM LONG REBAR
45.6 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - BROKEN MISSING REBAR
66.4 ft. - General Observation - TILES 50% INPLACE
85.6 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR
99.2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - MISSING REBAR
107.9 ft. - General Photograph
179.7 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES - BROKEN REBAR
275.6 ft. - Surface Missing Wall, from 01 to 02 o'clock, within 8 inches of joint: YES - SOIL VISIBLE
277.5 ft. - Surface Missing Wall, at 02 o'clock, within 8 inches of joint: NO - SOIL VISIBLE
277.5 ft. - General Photograph - SOIL VISIBLE
416.5 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN MISSING TILES
468 ft. - General Photograph
| Distance | Code | Observation |
|---|---|---|
| 380.6 | MGO | TILES 60% INPLACE |
| 277.5 | SMW | SOIL VISIBLE |
| 252.3 | DSZ | MISSING TILES |
| 275.6 | SMW | SOIL VISIBLE |
| 357.4 | TF | Active |
| 27.2 | DSZ | TILES & DEBRIE |
| 275.6 | TF | Active |
| 2 | SRC | CIRCUM & LONG REBAR CORRODED,BROKEN,MISSING |
| 302.9 | TF | Open |
| 66.4 | MGO | TILES 50% INPLACE |
| 252.3 | MWL | — |
| 0 | MGO | Conn. @ Mh, 3 O' Clock. Active |
| 20.7 | MWL | — |
| 2 | MGO | MISSING TILES 90% START 10;00 TO 2:00 |
| 45.6 | SRC | BROKEN MISSING REBAR |
| 0 | MWM | — |
| 498.5 | SRC | CIRCUM,LONG REBAR CORRODED,BROKEN,MISSING |
| 0 | AMH | 1:20AM |
| 85.6 | SRC | BROKEN MISSING REBAR |
| 498.5 | MGO | Conn. @ Mh, 9 O' Clock. Active |
| 498.5 | SRC | MISSING REBAR |
| 498.5 | MGO | Conn. @ Mh, 12 O' Clock. Capped |
| 498.8 | AMH | 3:30AM |
| 10.5 | TF | Active |
| 20.7 | MGO | 60% TILES IN PLACE |
| 99.2 | SRC | MISSING REBAR |
| 40.3 | SRC | CIRCUM LONG REBAR |
| 179.7 | SRC | BROKEN REBAR |
| 107.9 | MGP | — |
| 0 | MWL | — |
| 317.2 | TF | Open |
| 468 | MGP | — |
| 416.5 | SRC | BROKEN MISSING TILES |
| 498.5 | SAM | SEVERE AGG |
| 2 | SAM | SEVERE AGG |
| 277.5 | MGP | SOIL VISIBLE |
| 76.8 | MGO | TILES 100% MISSING |