Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 1, 2017, 06:00 PM
  • 08 0467_08 0466_212017_110049.mp4

Date
02/01/2017
W/O
0621922
Weather
Dry
Operator/Surveyor
MIRANDA
Sewer ID
Z00026
PipeID
P00523
Time
10:00 AM
Certificate
U-1014-06022542
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0424
Sewer Name
08 216TH STREET TRUNK
City
CARSON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
10
Purpose
Routine Assessment
Project
20170201AM_216TH_STREET_TRUNK
Material
RCP-CTL
Shape
Circular
Height
36 in.
Upstream MH
08 0467
Downstream MH
08 0466
Dir. of Survey
Downstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
4
Structural Quick
5231
Structural Rating
13
O&M Index
5
O&M Quick
5100
O&M Rating
5
Overall Index
5
Overall Quick
Overall Rating
18
Pipe schematic from manhole 08 0467 to 08 0466
MH: 08 0467MH: 08 0466downstream0 ft. AMH - Upstream Manhole, Survey Begins - 11:02 AM0 ft. MWL - Water Level, 90 %of cross sectional area0 ft. MWM - Water Mark, 90 %of cross sectional area2 ft. SAV - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES2 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES2 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO2 ft. MGO - General Observation - 100% MISSING TILES FROM 10 TO 02 O'CLOCK2.1 ft. MSA - Survey Abandoned - 90% WATER LEVEL

Observation photos (7)

  • Upstream Manhole, Survey Begins - 11:02 AM

    0 ft. - Upstream Manhole, Survey Begins - 11:02 AM

  • Water Level, 90 %of cross sectional area

    0 ft. - Water Level, 90 %of cross sectional area

  • Water Mark, 90 %of cross sectional area

    0 ft. - Water Mark, 90 %of cross sectional area

  • Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES

    2 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: YES

  • General Observation - 100% MISSING TILES FROM 10 TO 02 O'CLOCK

    2 ft. - General Observation - 100% MISSING TILES FROM 10 TO 02 O'CLOCK

  • Survey Abandoned - 90% WATER LEVEL

    2.1 ft. - Survey Abandoned - 90% WATER LEVEL

Observations (8)

DistanceCodeObservation
0AMH11:02 AM
2SAV
2SRV
0MWL
2SRC
2.1MSA90% WATER LEVEL
2MGO100% MISSING TILES FROM 10 TO 02 O'CLOCK
0MWM

Properties (4)

custom_field_three
BROKEN REBAR
custom_field_two
2
customer
LACSD
datetime
2017-02-01T10:00:59-08:00