01 1124_01 1123_1312017_092855.mp4
6 ft. - General Observation - CHIPPING @ 11 O'CLOCK
7.8 ft. - General Photograph - SPALLING 8 TO 4 O'CLOCK
16.8 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 4", 4" - OPEN/INTRUDING 1"
134.9 ft. - General Photograph - SPALLING
140.9 ft. - Crack Spiral, from 08 to 09 o'clock, within 8 inches of joint: YES
143.4 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES
156.1 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES
197 ft. - General Photograph - GREASE
262.1 ft. - General Photograph - SPALLING
265.5 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES
275.5 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES
278.2 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 101.6 | TF | OPEN |
| 279.6 | CM | — |
| 127 | TFA | — |
| 279.6 | SAVC | — |
| 0 | AMH | 9:26 AM |
| 0 | MGO | ROACHES @ MH |
| 236.3 | TFA | — |
| 2 | SSSC | — |
| 278.2 | CL | — |
| 6 | MGO | CHIPPING @ 11 O'CLOCK |
| 281.6 | AMH | 10:04 AM |
| 2 | CM | — |
| 134.9 | MGP | SPALLING |
| 198.3 | TFA | — |
| 156.1 | CL | — |
| 16.8 | TB | OPEN/INTRUDING 1" |
| 281.6 | MGO | ROACHES @ MH |
| 7.8 | MGP | SPALLING 8 TO 4 O'CLOCK |
| 140.9 | CS | — |
| 78.5 | TF | OPEN |
| 275.5 | CL | — |
| 134.7 | TFA | — |
| 197 | MGP | GREASE |
| 0 | MWL | — |
| 143.4 | CL | — |
| 0 | MWM | — |
| 2 | SAVC | — |
| 281.6 | MGO | GREASE THROUGHOUT THE REACH |
| 248.9 | TFA | — |
| 180.2 | TF | — |
| 262.1 | MGP | SPALLING |
| 228.3 | TF | OPEN |
| 279.6 | SSSC | — |
| 265.5 | CL | — |