Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 27, 2017, 05:24 PM
  • 01 1089_01 1088_1272017_092718.mp4

Date
01/27/2017
W/O
0613635
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00210
PipeID
P01938
Time
9:24 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7318
Sewer Name
01 HUNTINGTON PARK TRUNK
City
HUNTINGTON PARK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
08
Purpose
Capital Improvement Program Assesment
Project
20170127DF_HUNTINGTON_PARK_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Upstream MH
01 1089
Downstream MH
01 1088
Dir. of Survey
Downstream
Length Surveyed
522.8 ft.
Total Length
522.8 ft.
Structural Index
3
Structural Quick
4138
Structural Rating
32
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
32
Pipe schematic from manhole 01 1089 to 01 1088
MH: 01 1089MH: 01 1088downstream0 ft. AMH - Upstream Manhole, Survey Begins - 9:25 AM0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2 ft. SSSC - Surface Spalling Chemical, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SAVC - Surface Aggregate Visible Chemical, from 08 to 04 o'clock, within 8 inches of joint: YES, Start4.2 ft. SZC - Surface Other Chemical, from 03 to 09 o'clock, within 8 inches of joint: YES - GEASE @ JOINTS35.5 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES45.8 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES118.2 ft. SSSC - Surface Spalling Chemical, from 08 to 04 o'clock, within 8 inches of joint: YES314.7 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES363.4 ft. FS - Fracture Spiral, from 09 to 10 o'clock, within 8 inches of joint: YES, Start369.1 ft. FS - Fracture Spiral, from 09 to 10 o'clock, within 8 inches of joint: YES, Finish420 ft. FS - Fracture Spiral, from 09 to 11 o'clock, within 8 inches of joint: YES480.3 ft. B - Broken, from 12 to 02 o'clock, within 8 inches of joint: YES495 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES519.2 ft. SAVC - Surface Aggregate Visible Chemical, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish519.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish519.2 ft. SSSC - Surface Spalling Chemical, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish522.6 ft. MGO - General Observation - Conn. @ Mh, 5 O' Clock. Active522.7 ft. MGO - General Observation - ROACHES @ MH522.8 ft. AMH - Downstream Manhole, Survey Ends - 10:01 AM

Observation photos (8)

  • Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    35.5 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    45.8 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Surface Spalling Chemical, from 08 to 04 o'clock, within 8 inches of joint: YES

    118.2 ft. - Surface Spalling Chemical, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    314.7 ft. - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 09 to 10 o'clock, within 8 inches of joint: YES, Start

    363.4 ft. - Fracture Spiral, from 09 to 10 o'clock, within 8 inches of joint: YES, Start

  • Fracture Spiral, from 09 to 11 o'clock, within 8 inches of joint: YES

    420 ft. - Fracture Spiral, from 09 to 11 o'clock, within 8 inches of joint: YES

  • Broken, from 12 to 02 o'clock, within 8 inches of joint: YES

    480.3 ft. - Broken, from 12 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    495 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

Observations (23)

DistanceCodeObservation
519.2SAVC
314.7FL
0AMH9:25 AM
363.4FS
0MGOConn. @ Mh, 3 O' Clock. Active
522.6MGOConn. @ Mh, 5 O' Clock. Active
420FS
4.2SZCGEASE @ JOINTS
480.3B
35.5FL
2SSSC
0MWM
522.7MGOROACHES @ MH
118.2SSSC
0MWL
2CM
2SAVC
495FL
519.2CM
369.1FS
45.8FL
522.8AMH10:01 AM
519.2SSSC

Properties (3)

custom_field_two
2
customer
LACSD
datetime
2017-01-27T09:24:20-08:00