05 1545_05 1544A_1132017_093646.mp4
27.7 ft. - Surface Reinforcement Visible, from 08 to 12 o'clock, within 8 inches of joint: YES
156.3 ft. - Surface Other Chemical, from 10 to 11 o'clock, within 8 inches of joint: YES - PEELING/FLAKING
231.8 ft. - General Photograph - FLAKING
348.6 ft. - Roots Fine Barrell, at 03 o'clock, within 8 inches of joint: YES
348.6 ft. - Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: YES, 6", 6" - ACTIVE/ 30% GREASE
366.2 ft. - General Photograph - PEELING/FLAKING
407.4 ft. - Hole Void Visible, from 02 to 03 o'clock, within 8 inches of joint: YES
407.4 ft. - General Photograph - POSSIBLE REPAIR
407.4 ft. - General Photograph - HOLE IN PIPE
510.2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 08 o'clock, , within 8 inches of joint: YES
528.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 05 o'clock, , within 8 inches of joint: YES
633.3 ft. - Surface Reinforcement Projecting Unknown, from 10 to 11 o'clock, within 8 inches of joint: YES
| Distance | Code | Observation |
|---|---|---|
| 640.6 | MGO | GREASE THROUGHOUT THE REACH |
| 0.1 | MGO | Conn. @ Mh, 8 O' Clock. Active |
| 407.4 | HVV | — |
| 2 | SSSC | — |
| 0 | AMH | 9:18 AM |
| 360 | MWM | — |
| 643 | AMH | 10:32 AM |
| 478 | MWL | — |
| 640.6 | SAVC | — |
| 407.4 | MGP | POSSIBLE REPAIR |
| 231.8 | MGP | FLAKING |
| 27.7 | SRV | — |
| 528.1 | DAGS | — |
| 366.2 | MGP | PEELING/FLAKING |
| 348.6 | RFB | — |
| 640.6 | SRVC | — |
| 407.4 | MGP | HOLE IN PIPE |
| 633.3 | SRPZ | — |
| 640.6 | SZC | SPALLING |
| 27.7 | SRVC | — |
| 0.1 | MWL | — |
| 478 | MWM | — |
| 27.7 | SZC | PEELING/FLAKING |
| 0.1 | MWM | — |
| 156.3 | SZC | PEELING/FLAKING |
| 510.2 | DAGS | — |
| 348.6 | TFD | ACTIVE/ 30% GREASE |
| 640.6 | SSSC | — |
| 2 | SAVC | — |
| 642.5 | MGO | Conn. @ Mh, 3 O' Clock. Active |
| 360 | MWL | — |