Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 10, 2017, 08:55 AM
  • B 1500_B 1499_1102017_015527.mp4

Date
01/10/2017
W/O
0617231
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z01124
PipeID
P25615
Time
12:55 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0388
Sewer Name
B JOINT OUTFALL B - UNIT 6G
City
ALHAMBRA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
23
Purpose
Capital Improvement Program Assesment
Project
20170110MDM_JOINT_OUTFALL_B_UNIT_6G
Material
Vitrified Clay Pipe
Shape
Circular
Height
36 in.
Upstream MH
B 1500
Downstream MH
B 1499
Dir. of Survey
Downstream
Length Surveyed
606.3 ft.
Total Length
606.3 ft.
Structural Index
5
Structural Quick
5700
Structural Rating
35
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
5
Overall Quick
Overall Rating
35
Pipe schematic from manhole B 1500 to B 1499
MH: B 1500MH: B 1499downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:45AM1 ft. MGO - General Observation - CONSTRUCTION SITE MH B1503 IN LOCKED SCHOOL YARD1 ft. MGO - General Observation - CONSTRUCTION SITE MH#B1501 SMART COVER NO ACCESS1 ft. MGO - General Observation - CONSTRUCTION SITE MH#B1502 BY PASS MH NO ACCESS1 ft. MGO - General Observation - CONSTRUCTION SITE MH# B1500 ON SIDEWALK BEHIND 3 ROWS BY PASS PIPE19.6 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: NO - CORRODED VCP PIPE58.7 ft. SMW - Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: YES - SOIL VISIBLE1" X8"113.1 ft. MGO - General Observation - CAMERA FLIPPED OVER113.1 ft. SMW - Surface Missing Wall, from 01 to 03 o'clock, within 8 inches of joint: YES - SOIL VISIBLE VOID114.7 ft. SMW - Surface Missing Wall, from 10 to 11 o'clock, within 8 inches of joint: YES - SOIL VISIBLE VOID128 ft. SMW - Surface Missing Wall, from 09 to 03 o'clock, within 8 inches of joint: YES - SOIL VISIBLE VOID136.2 ft. MGP - General Photograph - END OF VOID205.5 ft. SMW - Surface Missing Wall, from 01 to 02 o'clock, within 8 inches of joint: YES - SOIL VISIBLE VOID213.9 ft. SMW - Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: YES - SOIL VISIBLE VOID281.7 ft. SMW - Surface Missing Wall, from 01 to 03 o'clock, within 8 inches of joint: YES - SOIL VISIBLE VOID606.3 ft. AMH - Downstream Manhole, Survey Ends - 2:45AM

Observation photos (9)

  • Surface Other, from 08 to 04 o'clock, within 8 inches of joint: NO - CORRODED VCP PIPE

    19.6 ft. - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: NO - CORRODED VCP PIPE

  • Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: YES - SOIL VISIBLE1" X8"

    58.7 ft. - Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: YES - SOIL VISIBLE1" X8"

  • Surface Missing Wall, from 01 to 03 o'clock, within 8 inches of joint: YES - SOIL VISIBLE VOID

    113.1 ft. - Surface Missing Wall, from 01 to 03 o'clock, within 8 inches of joint: YES - SOIL VISIBLE VOID

  • Surface Missing Wall, from 10 to 11 o'clock, within 8 inches of joint: YES - SOIL VISIBLE VOID

    114.7 ft. - Surface Missing Wall, from 10 to 11 o'clock, within 8 inches of joint: YES - SOIL VISIBLE VOID

  • Surface Missing Wall, from 09 to 03 o'clock, within 8 inches of joint: YES - SOIL VISIBLE VOID

    128 ft. - Surface Missing Wall, from 09 to 03 o'clock, within 8 inches of joint: YES - SOIL VISIBLE VOID

  • General Photograph - END OF  VOID

    136.2 ft. - General Photograph - END OF VOID

  • Surface Missing Wall, from 01 to 02 o'clock, within 8 inches of joint: YES - SOIL VISIBLE VOID

    205.5 ft. - Surface Missing Wall, from 01 to 02 o'clock, within 8 inches of joint: YES - SOIL VISIBLE VOID

  • Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: YES - SOIL VISIBLE VOID

    213.9 ft. - Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: YES - SOIL VISIBLE VOID

  • Surface Missing Wall, from 01 to 03 o'clock, within 8 inches of joint: YES - SOIL VISIBLE VOID

    281.7 ft. - Surface Missing Wall, from 01 to 03 o'clock, within 8 inches of joint: YES - SOIL VISIBLE VOID

Observations (18)

DistanceCodeObservation
205.5SMWSOIL VISIBLE VOID
58.7SMWSOIL VISIBLE1" X8"
128SMWSOIL VISIBLE VOID
1MGOCONSTRUCTION SITE MH B1503 IN LOCKED SCHOOL YARD
0MWL
281.7SMWSOIL VISIBLE VOID
1MGOCONSTRUCTION SITE MH#B1501 SMART COVER NO ACCESS
0MWM
19.6SZCORRODED VCP PIPE
213.9SMWSOIL VISIBLE VOID
113.1MGOCAMERA FLIPPED OVER
113.1SMWSOIL VISIBLE VOID
114.7SMWSOIL VISIBLE VOID
606.3AMH2:45AM
1MGOCONSTRUCTION SITE MH#B1502 BY PASS MH NO ACCESS
1MGOCONSTRUCTION SITE MH# B1500 ON SIDEWALK BEHIND 3 ROWS BY PASS PIPE
136.2MGPEND OF VOID
0AMH1:45AM

Properties (5)

custom_field_three
VOIDS SOIL VISIBLE
custom_field_two
1
customer
LACSD
datetime
2017-01-10T00:55:00-08:00
year_laid
20060616