18 0986_18 0971_12302016_130611.mp4
5 ft. - General Observation - CHIPPING ALL AROUND THE PIPE
5.6 ft. - Fracture Multiple, from 11 to 03 o'clock, within 8 inches of joint: YES
12.9 ft. - Broken, from 12 to 05 o'clock, within 8 inches of joint: YES
12.9 ft. - General Observation - BROKEN PIPE
16 ft. - Broken, from 11 to 01 o'clock, within 8 inches of joint: YES
18.4 ft. - Joint Offset Large
30.8 ft. - Tap Break-In Defective, at 11 o'clock, -, , within 8 inches of joint: YES, 4" - OPEN, BROKEN, 45% BLOCKED
30.9 ft. - General Photograph - DEFECTIVE CONN.
31.6 ft. - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN
31.6 ft. - Deposits Attached Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES - DEBRIS
33 ft. - Upstream Manhole, Survey Ends - 1:23 PM, STOPLOG IN PLACE
| Distance | Code | Observation |
|---|---|---|
| 7.5 | CM | — |
| 0 | MWM | — |
| 0 | MWL | — |
| 0 | MGO | ACTIVE CONN. INSIDE THE MH. @ 03 O'CLOCK |
| 0 | MGO | ROACHES INSIDE THE MH. |
| 0 | AMH | 1:05 PM |
| 16 | B | — |
| 13.2 | CM | — |
| 30.8 | TBD | OPEN, BROKEN, 45% BLOCKED |
| 32.5 | MGO | SLIGHT GREASE THROUGHOUT THE REACH |
| 30.9 | MGP | DEFECTIVE CONN. |
| 5 | MGO | CHIPPING ALL AROUND THE PIPE |
| 12.9 | B | — |
| 32.5 | MGO | CHIPPING ALL AROUND THE PIPE THROUGHOUT THE REACH |
| 18.4 | JOL | — |
| 32.5 | CM | — |
| 31.6 | FL | POSSIBLY BROKEN |
| 33 | AMH | 1:23 PM, STOPLOG IN PLACE |
| 12.9 | MGO | BROKEN PIPE |
| 5.6 | FM | — |
| 31.6 | DAZ | DEBRIS |