Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 30, 2016, 04:39 PM
  • 18 1228_18 1227_12302016_084251.mp4

Date
12/30/2016
W/O
0607773
Weather
Light Rain
Operator/Surveyor
MIRANDA
Sewer ID
Z01143
PipeID
P25608
Time
8:39 AM
Certificate
U-1014-06022542
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7302
Sewer Name
18 WORSHAM CREEK REPLACEMENT TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
11
Purpose
Capital Improvement Program Assesment
Project
20161230AM_WORSHAM_CREEK_REPLACEMENT_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
18 1228
Downstream MH
18 1227
Dir. of Survey
Downstream
Length Surveyed
371.3 ft.
Total Length
371.3 ft.
Structural Index
1
Structural Quick
1300
Structural Rating
3
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
1
Overall Quick
Overall Rating
5
Pipe schematic from manhole 18 1228 to 18 1227
MH: 18 1228MH: 18 1227downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 8:42 AM0 ft. MWM - Water Mark, 20 %of cross sectional area32.5 ft. MGO - General Observation - CHIPPING38.6 ft. MGO - General Observation - CHIPPING39.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"48.5 ft. MGO - General Observation - CHIPPING49.6 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"50 ft. MGO - General Observation - CHIPPING51.6 ft. MGO - General Observation - CHIPPING52.6 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6" - OPEN53.1 ft. MGO - General Observation - CHIPPING61.7 ft. MGO - General Observation - CHIPPING85.7 ft. MGO - General Observation - CHIPPING86.9 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6" - OPEN87.3 ft. MGO - General Observation - CHIPPING @ THE JOINTS, START88.3 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"99.1 ft. TFD - Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE, OFFSET138.7 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6" - OPEN159.5 ft. JOM - Joint Offset Medium172.7 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"196.9 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6" - OPEN206.7 ft. JOM - Joint Offset Medium238.2 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"246.7 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6" - OPEN256.6 ft. JOM - Joint Offset Medium270.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"287.8 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6" - OPEN326.8 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 6" - OPEN345.9 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"349.3 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - OPEN368.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN369.3 ft. MGO - General Observation - SLIGHT GREASE THROUGHOUT THE REACH369.3 ft. MGO - General Observation - SPIDER WEBS THROUGHOUT THE REACH369.6 ft. MGO - General Observation - CHIPPING @ THE JOINTS, FINISH369.6 ft. MGO - General Observation - ACTIVE CONN. INSIDE THE MH. @ 03 O'CLOCK371.3 ft. AMH - Downstream Manhole, Survey Ends - 9:32 AM371.3 ft. MGO - General Observation - ROACHES INSIDE THE MH.

Observation photos (11)

  • Water Level, 10 %of cross sectional area

    0 ft. - Water Level, 10 %of cross sectional area

  • Upstream Manhole, Survey Begins - 8:42 AM

    0 ft. - Upstream Manhole, Survey Begins - 8:42 AM

  • Water Mark, 20 %of cross sectional area

    0 ft. - Water Mark, 20 %of cross sectional area

  • General Observation - CHIPPING

    32.5 ft. - General Observation - CHIPPING

  • General Observation - CHIPPING

    85.7 ft. - General Observation - CHIPPING

  • Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE, OFFSET

    99.1 ft. - Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE, OFFSET

  • Joint Offset Medium

    159.5 ft. - Joint Offset Medium

  • Joint Offset Medium

    206.7 ft. - Joint Offset Medium

  • Joint Offset Medium

    256.6 ft. - Joint Offset Medium

  • Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - OPEN

    349.3 ft. - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 6" - OPEN

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN

    368.6 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN

Observations (38)

DistanceCodeObservation
38.6MGOCHIPPING
32.5MGOCHIPPING
61.7MGOCHIPPING
369.6MGOCHIPPING @ THE JOINTS, FINISH
371.3AMH9:32 AM
349.3TFOPEN
53.1MGOCHIPPING
206.7JOM
49.6TFA
48.5MGOCHIPPING
371.3MGOROACHES INSIDE THE MH.
369.3MGOSLIGHT GREASE THROUGHOUT THE REACH
0MWL
326.8TFOPEN
0AMH8:42 AM
50MGOCHIPPING
138.7TFOPEN
85.7MGOCHIPPING
87.3MGOCHIPPING @ THE JOINTS, START
51.6MGOCHIPPING
256.6JOM
99.1TFDACTIVE, OFFSET
238.2TFA
196.9TFOPEN
86.9TFOPEN
345.9TFA
52.6TFOPEN
287.8TFOPEN
0MWM
270.2TFA
246.7TFOPEN
369.3MGOSPIDER WEBS THROUGHOUT THE REACH
159.5JOM
369.6MGOACTIVE CONN. INSIDE THE MH. @ 03 O'CLOCK
368.6TFOPEN
39.5TFA
172.7TFA
88.3TFA

Properties (4)

custom_field_two
3
customer
LACSD
datetime
2016-12-30T08:39:31-08:00
year_laid
20051102