Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 23, 2016, 07:00 PM
  • 29 0090_29 0089_12232016_110606.mp4

Date
12/23/2016
W/O
0607761
Weather
Damp
Operator/Surveyor
FRANKLIN
Sewer ID
Z00265
PipeID
P23870
Time
11:00 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7298
Sewer Name
29 33RD STREET TRUNK
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
01
Purpose
Routine Assessment
Project
20161223DF_33RD_STREET_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
29 0089
Downstream MH
29 0090
Dir. of Survey
Upstream
Length Surveyed
321.6 ft.
Total Length
321.6 ft.
Structural Index
5
Structural Quick
5100
Structural Rating
5
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole 29 0089 to 29 0090
MH: 29 0089MH: 29 0090upstream0 ft. AMH - Upstream Manhole, Survey Ends - 11:46 AM0 ft. MGO - General Observation - ROACHES @ MH0.6 ft. B - Broken, from 04 to 06 o'clock, within 8 inches of joint: YES9.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"86.1 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN107.8 ft. TFI - Tap Factory Made Intruding, at 10 o'clock, -, -, within 8 inches of joint: YES, 4", 1" - OPEN260.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"311.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 4"321.5 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active321.5 ft. MWL - Water Level, 5 %of cross sectional area321.5 ft. MWM - Water Mark, 10 %of cross sectional area321.5 ft. MGO - General Observation - ROACHES @ MH321.6 ft. AMH - Downstream Manhole, Survey Begins - 11:00 AM

Observation photos (3)

  • Tap Factory Made Intruding, at 10 o'clock, -, -, within 8 inches of joint: YES, 4", 1" -  OPEN

    213.8 ft. - Tap Factory Made Intruding, at 10 o'clock, -, -, within 8 inches of joint: YES, 4", 1" - OPEN

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN

    235.5 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN

  • Broken, from 04 to 06 o'clock, within 8 inches of joint: YES

    321 ft. - Broken, from 04 to 06 o'clock, within 8 inches of joint: YES

Observations (13)

DistanceCodeObservation
213.8TFIOPEN
235.5TBOPEN
321.6AMH11:46 AM
0.1MGOConn. @ Mh, 3 O' Clock. Active
9.7TFC
311.9TFC
0.1MWL
0.1MWM
61.5TFC
321B
0AMH11:00 AM
0.1MGOROACHES @ MH
321.6MGOROACHES @ MH

Properties (3)

custom_field_two
4
customer
LACSD
datetime
2016-12-23T11:00:09-08:00