Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 1, 2016, 04:21 PM
  • 29 0249_29 0248_1212016_111614.mp4

Date
12/01/2016
W/O
0607759
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z01015
PipeID
P24152
Time
8:21 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7285
Sewer Name
29 EASTSIDE INTERCEPTOR SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
02
Purpose
Routine Assessment
Project
20161201DF_EASTSIDE_INTERCEPTOR_SEWER
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
29 0248
Downstream MH
29 0249
Dir. of Survey
Upstream
Length Surveyed
100.2 ft.
Total Length
100.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 29 0248 to 29 0249
MH: 29 0248MH: 29 0249upstream0 ft. AMH - Upstream Manhole, Survey Ends - 11:27 AM0 ft. MGP - General Photograph - CAP/BEGGINNING OF LINE DEFECTIVE0.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4" - OPEN5.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"23.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 4"92.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN100.1 ft. MWL - Water Level, 5 %of cross sectional area100.1 ft. MWM - Water Mark, 10 %of cross sectional area100.2 ft. AMH - Downstream Manhole, Survey Begins - 11:18 AM

Observation photos (1)

  • General Photograph - CAP/BEGGINNING OF LINE DEFECTIVE

    100.2 ft. - General Photograph - CAP/BEGGINNING OF LINE DEFECTIVE

Observations (9)

DistanceCodeObservation
0.1MWL
100.2AMH11:27 AM
100.2MGPCAP/BEGGINNING OF LINE DEFECTIVE
99.4TFOPEN
0AMH11:18 AM
8TFOPEN
76.7TFA
0.1MWM
94.4TFA

Properties (3)

custom_field_two
4
customer
LACSD
datetime
2016-12-01T08:21:49-08:00