Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 28, 2016, 12:06 PM
  • 02 0093_02 0092_11282016_041821.mp4

Date
11/28/2016
W/O
0602393
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00237
PipeID
P02259
Time
4:06 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0345
Sewer Name
02 BELLFLOWER TRUNK
City
BELLFLOWER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
38
Purpose
Routine Assessment
Project
20161128MDM_BELLFLOWER_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
02 0092
Downstream MH
02 0093
Dir. of Survey
Upstream
Length Surveyed
274.7 ft.
Total Length
274.7 ft.
Structural Index
3
Structural Quick
3222
Structural Rating
10
O&M Index
3
O&M Quick
4121
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
16
Pipe schematic from manhole 02 0092 to 02 0093
MH: 02 0092MH: 02 0093upstream0 ft. AMH - Upstream Manhole, Survey Ends - 4:35AM0.5 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active4.6 ft. FC - Fracture Circumferential, from 10 to 11 o'clock, within 8 inches of joint: YES - H32.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped35.6 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H35.6 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - H67.3 ft. MWM - Water Mark, 40 %of cross sectional area84.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped118.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - HAIRLINE134.9 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES134.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Active192.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open220.9 ft. MGO - General Observation - 18" VCP246.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Peeling & Flaking Throughout The Reach274.7 ft. MWM - Water Mark, 50 %of cross sectional area274.7 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. OPEN274.7 ft. AMH - Downstream Manhole, Survey Begins - 4:10AM274.7 ft. MWL - Water Level, 15 %of cross sectional area

Observation photos (1)

  • General Observation - 18" VCP

    53.8 ft. - General Observation - 18" VCP

Observations (18)

DistanceCodeObservation
82TFOpen
274.2MGOConn. @ Mh, 3 O' Clock. Active
274.7AMH4:35AM
239.1FLH
0MWM
139.8DAGS
0MGOConn. @ Mh, 3 O' Clock. OPEN
156.2FLHAIRLINE
0AMH4:10AM
139.8TFActive
0MWL
207.4MWM
190.5TFCCapped
239.1FCH
53.8MGO18" VCP
270.1FCH
242.5TFCCapped
28.3TFCPeeling & Flaking Throughout The Reach

Properties (2)

customer
LACSD
datetime
2016-11-28T04:06:44-08:00