Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 21, 2016, 08:24 AM
  • A 0843_C 0569_11212016_004544.mp4

Date
11/21/2016
W/O
0602265
Weather
Heavy Rain
Operator/Surveyor
MARTIN
Sewer ID
Z00362
PipeID
P05252
Time
12:24 AM
Certificate
U-104-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0351
Sewer Name
C JOINT OUTFALL C - UNIT 4D
City
LAKEWOOD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
08
Purpose
Capital Improvement Program Assesment
Project
20161121MDM_JOINT_OUTFALL_C_UNIT_4D
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Upstream MH
A 0843
Downstream MH
C 0569
Dir. of Survey
Downstream
Length Surveyed
336.8 ft.
Total Length
336.8 ft.
Structural Index
2
Structural Quick
3224
Structural Rating
14
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
14
Pipe schematic from manhole A 0843 to C 0569
MH: A 0843MH: C 0569downstream0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active OUTGOING0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 12 O' Clock. Active0 ft. AMH - Upstream Manhole, Survey Begins - 12:55AM8 ft. MGO - General Observation - 27" VCP34.5 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - SLIGHT50.9 ft. MGO - General Observation - WHITE COATING OR BUILDUP ON PIPE176.2 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: YES - HAIRLINE209.7 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H272.9 ft. FC - Fracture Circumferential, from 11 to 12 o'clock, within 8 inches of joint: YES - SL289.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H317.9 ft. FC - Fracture Circumferential, from 10 to 11 o'clock, within 8 inches of joint: YES - H336.8 ft. AMH - Downstream Manhole, Survey Ends - 1:25AM

Observation photos (2)

  • General Observation - 27" VCP

    8 ft. - General Observation - 27" VCP

  • General Observation - WHITE COATING OR BUILDUP ON PIPE

    50.9 ft. - General Observation - WHITE COATING OR BUILDUP ON PIPE

Observations (15)

DistanceCodeObservation
0MGOConn. @ Mh, 9 O' Clock. Active OUTGOING
0MWM
272.9FCSL
317.9FCH
34.5FCSLIGHT
0MGOConn. @ Mh, 3 O' Clock. Active
8MGO27" VCP
289.8FLH
336.8AMH1:25AM
50.9MGOWHITE COATING OR BUILDUP ON PIPE
176.2FCHAIRLINE
0MWL
0MGOConn. @ Mh, 12 O' Clock. Active
0AMH12:55AM
209.7FLH

Properties (4)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2016-11-21T00:24:45-08:00