Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 16, 2016, 04:17 PM
  • 05 1369_05 1368_11162016_103535.mp4

  • 05 1369_05 1368_11162016_113448.mp4

Date
11/16/2016
W/O
0602258
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00444
PipeID
P06587
Time
8:17 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7275
Sewer Name
05 GARDENA PUMP TRUNK
City
GARDENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
18
Purpose
Capital Improvement Program Assesment
Project
20161116DF_GARDENA_PUMP_TRUNK
Material
NRCP
Shape
Circular
Height
10 in.
Upstream MH
05 1369
Downstream MH
05 1368
Dir. of Survey
Downstream
Length Surveyed
319.3 ft.
Total Length
319.3 ft.
Structural Index
3
Structural Quick
5146
Structural Rating
80
O&M Index
1
O&M Quick
2114
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
86
Pipe schematic from manhole 05 1369 to 05 1368
MH: 05 1369MH: 05 1368downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 10:34 AM2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start4.5 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES17.8 ft. RFL - Roots Fine Lateral, at 12 o'clock - 25%19.8 ft. RFJ - Roots Fine Joint, from 10 to 11 o'clock, within 8 inches of joint: YESR19.8 ft. TFD - Tap Factory Made Defective, at 12 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE, 25%27.2 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Start32.5 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES37.9 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES40.3 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start40.3 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES42.8 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES45.5 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start45.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES58.3 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - POSSIBLE BROKEN60.8 ft. FM - Fracture Multiple, from 10 to 12 o'clock, within 8 inches of joint: YES66.9 ft. RFL - Roots Fine Lateral, at 12 o'clock - 5%66.9 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"67.6 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR, Finish94.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES97.1 ft. BSV - Broken Soil Visible, at 12 o'clock, within 8 inches of joint: YES98.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - OPEN101.9 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES107.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start118.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6"158.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish161.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES169.6 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"181.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES184.1 ft. FM - Fracture Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES186.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start194.7 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish207 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES217.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES233.4 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"268.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES271.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES284.9 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"304.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES313 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6"317 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish317 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish317 ft. MGO - General Observation - SLIGHT GREASE THROUGHOUT THE REACH317 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish317 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish319.3 ft. MGO - General Observation - ROACHES319.3 ft. AMH - Downstream Manhole, Survey Ends - 12:01 PM

Observation photos (25)

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    4.5 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Roots Fine Lateral, at 12 o'clock - 25%

    17.8 ft. - Roots Fine Lateral, at 12 o'clock - 25%

  • Roots Fine Joint, from 10 to 11 o'clock, within 8 inches of joint: YESR

    19.8 ft. - Roots Fine Joint, from 10 to 11 o'clock, within 8 inches of joint: YESR

  • Tap Factory Made Defective, at 12 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE, 25%

    19.8 ft. - Tap Factory Made Defective, at 12 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE, 25%

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    32.5 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    37.9 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    40.3 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    42.8 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

    45.5 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    45.5 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - POSSIBLE BROKEN

    58.3 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - POSSIBLE BROKEN

  • Fracture Multiple, from 10 to 12 o'clock, within 8 inches of joint: YES

    60.8 ft. - Fracture Multiple, from 10 to 12 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    94.2 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Broken Soil Visible, at 12 o'clock, within 8 inches of joint: YES

    97.1 ft. - Broken Soil Visible, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    101.9 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    107.2 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    161.2 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    181.6 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES

    184.1 ft. - Fracture Multiple, from 12 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    186.6 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    207 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    217.6 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    268.8 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    271.5 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    304.6 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

Observations (50)

DistanceCodeObservation
58.3FLPOSSIBLE BROKEN
317CM
4.5CL
19.8RFJ
45.5CM
186.6FL
0MWL
60.8FM
319.3MGOROACHES
19.8TFDACTIVE, 25%
101.9FL
98.7TFOPEN
169.6TFA
184.1FM
194.7FL
118.2TFC
217.6FL
0MWM
317CL
317MGOSLIGHT GREASE THROUGHOUT THE REACH
233.4TFA
37.9FM
268.8FL
17.8RFL25%
45.5FL
284.9TFA
94.2FL
0AMH10:34 AM
67.6RFJ
271.5FL
207FL
181.6FL
317SSS
40.3CL
32.5FM
42.8FM
66.9RFL5%
107.2FL
319.3AMH12:01 PM
2SSS
40.3FM
2SAV
313TFC
66.9TFA
317SAV
158.5FL
27.2RFJ
161.2FL
97.1BSV
304.6FL

Properties (3)

custom_field_two
1
customer
LACSD
datetime
2016-11-16T08:17:03-08:00