Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 16, 2016, 08:28 AM
  • 02 1140_02 1139_11162016_004020.mp4

Date
11/16/2016
W/O
0607058
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00351
PipeID
P02923
Time
12:28 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0344
Sewer Name
02 GARFIELD AVENUE EXTENSION TRUNK
City
MONTEBELLO
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
13
Purpose
Maintenance Related
Project
20161115MDM_GARFIELD_AVENUE_EXTENSION_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
02 1140
Downstream MH
02 1139
Dir. of Survey
Downstream
Length Surveyed
299.7 ft.
Total Length
299.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
1
O&M Quick
1100
O&M Rating
1
Overall Index
1
Overall Quick
Overall Rating
1
Pipe schematic from manhole 02 1140 to 02 1139
MH: 02 1140MH: 02 1139downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 12:30AM0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Capped14.9 ft. RFJ - Roots Fine Joint, from 08 to 09 o'clock, within 8 inches of joint: YESR - 1%141.9 ft. TB - Tap Break-In, at 03 o'clock, -, within 8 inches of joint: YES, 6", 6" - Open145.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped154.1 ft. MGO - General Observation - 15" VCP180.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped231.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped266.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped294.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped299.7 ft. AMH - Downstream Manhole, Survey Ends - 12:50AM

Observation photos (1)

  • General Observation - 15" VCP

    154.1 ft. - General Observation - 15" VCP

Observations (14)

DistanceCodeObservation
0MWM
154.1MGO15" VCP
141.9TBOpen
0AMH12:30AM
231.7TFCCapped
0MGOConn. @ Mh, 3 O' Clock. Active
266.3TFCCapped
180.3TFCCapped
0MWL
299.7AMH12:50AM
0MGOConn. @ Mh, 9 O' Clock. Capped
145.6TFCCapped
14.9RFJ1%
294.1TFCCapped

Properties (4)

additional_info
ROOT & GREASE EVALUATION
custom_field_two
4
customer
LACSD
datetime
2016-11-16T00:28:48-08:00