C 0653_C 0652_10292016_093650.mp4
14.2 ft. - Joint Separated Medium
18.9 ft. - General Observation - CHIPPING
59.8 ft. - Joint Separated Medium
97.9 ft. - Fracture Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN
155.5 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
196.4 ft. - Fracture Multiple, from 07 to 11 o'clock, within 8 inches of joint: YES
274.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES
306.9 ft. - General Observation - SEPARATED JOINTS THROUGHOUT THE REACH
307.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish
310.1 ft. - Downstream Manhole, Survey Ends - 10:03 AM, PIPE DROPS INTO THE MH.
| Distance | Code | Observation |
|---|---|---|
| 18.9 | MGO | CHIPPING |
| 139 | CM | — |
| 274.6 | FM | — |
| 0 | MGO | ROACHES INSIDE THE MH. |
| 266.1 | MWL | — |
| 0 | AMH | 9:36 AM |
| 147.2 | CM | — |
| 0 | MWM | — |
| 196.4 | FM | — |
| 59.8 | CM | — |
| 306.9 | MGO | SEPARATED JOINTS THROUGHOUT THE REACH |
| 101.7 | JSM | — |
| 310.1 | AMH | 10:03 AM, PIPE DROPS INTO THE MH. |
| 0 | MWL | — |
| 155.5 | CM | — |
| 307.2 | CM | — |
| 59.8 | JSM | — |
| 81 | CM | — |
| 310.1 | MGO | SLIGHT GREASE/OIL THROUGHOUT THE REACH |
| 101.7 | CM | — |
| 309.9 | MGO | ROACHES INSIDE THE MH. |
| 97.9 | FM | POSSIBLY BROKEN |
| 14.2 | JSM | — |