2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
2 ft. - General Observation - MAG COAT 30% 8:00 TO 4:00 START
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE
13.3 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE SEVERE AGG ATTACHED
19 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - MULTI LAYER PEELING CONCRETE
30.8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - PEELING CONCRETE
89.1 ft. - General Observation - MAG COAT 40% START
157.2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO
267.5 ft. - General Observation - MAG COAT 60% SRART
| Distance | Code | Observation |
|---|---|---|
| 348.2 | SSS | PEELING CONCRETE |
| 0 | MWL | — |
| 267.5 | MGO | MAG COAT 60% SRART |
| 157.2 | SSS | — |
| 2 | SAM | SEVERE AGG |
| 30.8 | SSS | PEELING CONCRETE |
| 89.1 | MGO | MAG COAT 40% START |
| 348.2 | SAM | SEVERE AGG |
| 2 | MGO | MAG COAT 30% 8:00 TO 4:00 START |
| 0 | MWM | — |
| 348.2 | MGO | MAG COAT 60% FINISH |
| 348.6 | AMH | 4:55AM |
| 19 | SSS | MULTI LAYER PEELING CONCRETE |
| 2 | SSS | PEELING CONCRETE |
| 0 | AMH | 4:25AM |
| 13.3 | SSS | PEELING CONCRETE SEVERE AGG ATTACHED |