Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 14, 2016, 07:40 AM
  • 05 1045_05 0115_10142016_051155.mp4

Date
10/14/2016
W/O
0596927
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00441
PipeID
P06280
Time
12:40 AM
Certificate
U-101406022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0322
Sewer Name
05 FLOWER STREET TRUNK
City
HAWTHORNE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
13
Purpose
Capital Improvement Program Assesment
Project
20161014MDM_FLOWER_STREET_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
05 1045
Downstream MH
05 0115
Dir. of Survey
Downstream
Length Surveyed
334.7 ft.
Total Length
334.7 ft.
Structural Index
3
Structural Quick
5336
Structural Rating
53
O&M Index
2
O&M Quick
4112
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
59
Pipe schematic from manhole 05 1045 to 05 0115
MH: 05 1045MH: 05 0115downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 4:50AM0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Capped0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active1.8 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - SLIGHT3.9 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - S7 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - HAIRLINE10.8 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open13.1 ft. SMW - Surface Missing Wall, from 09 to 12 o'clock, within 8 inches of joint: YES - 1" X4"-VOID13.1 ft. SMW - Surface Missing Wall, from 09 to 11 o'clock, within 8 inches of joint: YES - MISSING & BROKEN PIPE14 ft. RFL - Roots Fine Lateral, from 09 to 12 o'clock - 5%14 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Active15.6 ft. RFJ - Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YESR - 5%28 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - S30.8 ft. MWL - Water Level, 10 %of cross sectional area30.8 ft. MWM - Water Mark, 20 %of cross sectional area43.3 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - S43.3 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - S52.9 ft. FC - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - S54.4 ft. TBI - Tap Break-In Intruding, at 02 o'clock, -, -, within 8 inches of joint: YES, 6", 2"INTRUDING - Active54.8 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - S55.5 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - HAIRLINE55.5 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - S58.4 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT AT JOINTS58.4 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Start - SLIGHT AT JOINTS58.4 ft. FL - Fracture Longitudinal, at 08 TO 4 o'clock, within 8 inches of joint: YES, Start - HAIRLINE AT JOINTS58.4 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - HAIRLINE AT JOINTS84.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Change - SLIGHT119.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Change - SLIGHT126.9 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Capped138.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped141.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open151.8 ft. MWL - Water Level, 20 %of cross sectional area163.6 ft. MWL - Water Level, 30 %of cross sectional area176.4 ft. MWL - Water Level, 10 %of cross sectional area186.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open207.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped210.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open210.6 ft. B - Broken, from 01 to 03 o'clock, within 8 inches of joint: YES - SLIGHT FRACTURE INDENTED255.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open257.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open294 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open296.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped334.2 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SLIGHT 30%334.2 ft. FL - Fracture Longitudinal, at 08 TO 4o'clock, within 8 inches of joint: YES, Finish - SLIGHT 15%334.2 ft. FL - Fracture Longitudinal, at 08 TO 4 o'clock, within 8 inches of joint: YES, Finish - HAIRLINE 15%334.2 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - HAIRLINE 30%334.7 ft. AMH - Downstream Manhole, Survey Ends - 5:50AM

Observation photos (5)

  • Surface Missing Wall, from 09 to 12 o'clock, within 8 inches of joint: YES - 1" X4"-VOID

    13.1 ft. - Surface Missing Wall, from 09 to 12 o'clock, within 8 inches of joint: YES - 1" X4"-VOID

  • Surface Missing Wall, from 09 to 11 o'clock, within 8 inches of joint: YES - MISSING & BROKEN PIPE

    13.1 ft. - Surface Missing Wall, from 09 to 11 o'clock, within 8 inches of joint: YES - MISSING & BROKEN PIPE

  • Tap Break-In Intruding, at 02 o'clock, -, -, within 8 inches of joint: YES, 6", 2"INTRUDING - Active

    54.4 ft. - Tap Break-In Intruding, at 02 o'clock, -, -, within 8 inches of joint: YES, 6", 2"INTRUDING - Active

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Change - SLIGHT

    119.5 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Change - SLIGHT

  • Broken, from 01 to 03 o'clock, within 8 inches of joint: YES - SLIGHT FRACTURE INDENTED

    210.6 ft. - Broken, from 01 to 03 o'clock, within 8 inches of joint: YES - SLIGHT FRACTURE INDENTED

Observations (49)

DistanceCodeObservation
54.8FLS
141.1TFOpen
0MWL
7FCHAIRLINE
334.7AMH5:50AM
58.4FCSLIGHT AT JOINTS
55.5FCHAIRLINE
334.2FCSLIGHT 30%
0AMH4:50AM
0MWM
257.8TFOpen
210.6BSLIGHT FRACTURE INDENTED
186.2TFOpen
58.4FLSLIGHT AT JOINTS
58.4FLHAIRLINE AT JOINTS
138.5TFCCapped
30.8MWL
126.9TFCCapped
296.8TFCCapped
10.8TBOpen
14RFL5%
119.5FLSLIGHT
55.5FLS
163.6MWL
28FCS
13.1SMW1" X4"-VOID
0MGOConn. @ Mh, 3 O' Clock. Capped
43.3FCS
84.2FLSLIGHT
1.8FCSLIGHT
52.9FCS
54.4TBIActive
14TFActive
334.2FLSLIGHT 15%
43.3FCS
151.8MWL
3.9FCS
334.2FLHAIRLINE 15%
334.2FCHAIRLINE 30%
15.6RFJ5%
58.4FCHAIRLINE AT JOINTS
210.1TFOpen
13.1SMWMISSING & BROKEN PIPE
294TFOpen
176.4MWL
207.4TFCCapped
30.8MWM
0MGOConn. @ Mh, 9 O' Clock. Active
255.2TFOpen

Properties (4)

custom_field_three
MISSING WALL-BROKEN PIPE-VOID
custom_field_two
1
customer
LACSD
datetime
2016-10-14T00:40:32-07:00