Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 6, 2016, 11:41 AM
  • 02 1825_02 1824_1062016_045044.mp4

Date
10/06/2016
W/O
0596932
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00236
PipeID
P04172
Time
4:41 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0313
Sewer Name
02 ATLANTIC AVENUE RELIEF TRUNK
City
LOS ANGLES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
10161006MDM_ATLANTIC_AVENUE_RELIEF_TRUNK
Material
NRCP
Shape
Circular
Height
18 in.
Upstream MH
02 1825
Downstream MH
02 1824
Dir. of Survey
Downstream
Length Surveyed
360.9 ft.
Total Length
360.9 ft.
Structural Index
2
Structural Quick
3127
Structural Rating
17
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
17
Pipe schematic from manhole 02 1825 to 02 1824
MH: 02 1825MH: 02 1824downstream0 ft. AMH - Upstream Manhole, Survey Begins - 4:50AM0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING CONCRETE2 ft. MGO - General Observation - MAG COAT 40% START2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG7.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - FLAKING CONCRETE19.3 ft. SSS - Surface Spalling, from 02 to 04 o'clock, within 8 inches of joint: NO, Start - PEELING CONCRETE26.3 ft. SSS - Surface Spalling, from 02 to 04 o'clock, within 8 inches of joint: NO, Finish - PEELING CONCRET FINISH41.9 ft. SSS - Surface Spalling, from 08 to 11 o'clock, within 8 inches of joint: NO - PEELING CONCRETE103.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE163.3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - PEELING CONCRETE225.6 ft. MGO - General Observation - MAG COAT 20% START238.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - PEELING CONCRETE246.6 ft. MGP - General Photograph - PEELING CONCRETE WITH SEVERE AGG360.5 ft. MGO - General Observation - MAG COAT FINISH360.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG360.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - FLAKING CONCRETE360.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - PEELING CONCRETE360.9 ft. AMH - Downstream Manhole, Survey Ends - 5:25AM

Observation photos (11)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - FLAKING CONCRETE

  • General Observation - MAG COAT 40% START

    2 ft. - General Observation - MAG COAT 40% START

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - FLAKING CONCRETE

    7.4 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - FLAKING CONCRETE

  • Surface Spalling, from 02 to 04 o'clock, within 8 inches of joint: NO, Start - PEELING CONCRETE

    19.3 ft. - Surface Spalling, from 02 to 04 o'clock, within 8 inches of joint: NO, Start - PEELING CONCRETE

  • Surface Spalling, from 08 to 11 o'clock, within 8 inches of joint: NO - PEELING CONCRETE

    41.9 ft. - Surface Spalling, from 08 to 11 o'clock, within 8 inches of joint: NO - PEELING CONCRETE

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE

    103.4 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - PEELING CONCRETE

    163.3 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - PEELING CONCRETE

  • General Observation - MAG COAT 20% START

    225.6 ft. - General Observation - MAG COAT 20% START

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - PEELING CONCRETE

    238.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - PEELING CONCRETE

  • General Photograph - PEELING CONCRETE WITH SEVERE AGG

    246.6 ft. - General Photograph - PEELING CONCRETE WITH SEVERE AGG

Observations (20)

DistanceCodeObservation
2SSSFLAKING CONCRETE
0AMH4:50AM
7.4SSSFLAKING CONCRETE
103.4SSSPEELING CONCRETE
26.3SSSPEELING CONCRET FINISH
360.5MGOMAG COAT FINISH
238.1SSSPEELING CONCRETE
163.3SSSPEELING CONCRETE
360.5SAPSEVERE AGG
225.6MGOMAG COAT 20% START
19.3SSSPEELING CONCRETE
360.5SSSFLAKING CONCRETE
0MWM
360.9AMH5:25AM
41.9SSSPEELING CONCRETE
2MGOMAG COAT 40% START
360.5SSSPEELING CONCRETE
2SAPSEVERE AGG
0MWL
246.6MGPPEELING CONCRETE WITH SEVERE AGG

Properties (4)

custom_field_three
PEELING CONCRET - SEVERE PROJECTING AGG
custom_field_two
2
customer
LACSD
datetime
2016-10-06T04:41:52-07:00