Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 13, 2016, 09:36 AM
Date
09/13/2016
W/O
0585465
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z00728
PipeID
P15216
Time
2:36 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0274
Sewer Name
19 STUDEBAKER ROAD TRUNK
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
04
Purpose
Routine Assessment
Project
20190913VMR_STUDEBAKER_ROAD_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
19 0246
Downstream MH
19 0245
Dir. of Survey
Downstream
Length Surveyed
262.7 ft.
Total Length
262.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 19 0246 to 19 0245
MH: 19 0246MH: 19 0245downstream0 ft. AMH - Upstream Manhole, Survey Begins - 03:58 AM0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area87.9 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 4"105.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"201.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"224.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"262.7 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 8"262.7 ft. AMH - Downstream Manhole, Survey Ends - 04:20 AM

Observations (9)

DistanceCodeObservation
201.4TF
0AMH03:58 AM
224.9TF
0MWL
262.7TFA
0MWM
262.7AMH04:20 AM
87.9TF
105.4TF

Properties (3)

custom_field_two
4
customer
LACSD
datetime
2016-09-13T02:36:33-07:00