- Date
- 09/29/2016
- W/O
- 0591702
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00013
- PipeID
- P00363
- Time
- 4:45 AM
- Certificate
- U-1014-O602543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H0298
- Sewer Name
- 08 KEYSTONE TRUNK
- City
- CARSON
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 10
- Purpose
- Capital Improvement Program Assesment
- Project
- 20160929MDM_KEYSTONE_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Upstream MH
- 08 0316
- Downstream MH
- 08 0315
- Dir. of Survey
- Downstream
- Length Surveyed
- 250.7 ft.
- Total Length
- 250.7 ft.
- Structural Index
- 3
- Structural Quick
- 3D2C
- Structural Rating
- 105
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 105
Pipe schematic from manhole 08 0316 to 08 0315 Observation photos (5)

11.4 ft. - General Observation - 15" VCP

98.5 ft. - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Start - H

104.4 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES, Start - SLIGHT

106.8 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Start - S

131.2 ft. - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Start - S