Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 29, 2016, 08:49 AM
  • 08 0317_08 0316_9292016_033305.mp4

Date
09/29/2016
W/O
0591702
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00013
PipeID
P00364
Time
1:49 AM
Certificate
U-1014-O602543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0298
Sewer Name
08 KEYSTONE TRUNK
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
10
Purpose
Capital Improvement Program Assesment
Project
20160929MDM_KEYSTONE_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
08 0317
Downstream MH
08 0316
Dir. of Survey
Downstream
Length Surveyed
349.8 ft.
Total Length
349.8 ft.
Structural Index
2
Structural Quick
4136
Structural Rating
80
O&M Index
2
O&M Quick
2211
O&M Rating
5
Overall Index
2
Overall Quick
Overall Rating
85
Pipe schematic from manhole 08 0317 to 08 0316
MH: 08 0317MH: 08 0316downstream0 ft. AMH - Upstream Manhole, Survey Begins - 3:30AM0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active0 ft. MWM - Water Mark, 20 %of cross sectional area5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT9.3 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - SLIGHT9.3 ft. FC - Fracture Circumferential, from 10 to 11 o'clock, within 8 inches of joint: YES - S14.5 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - S14.5 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - S15.4 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - HAIRLINE15.4 ft. FC - Fracture Circumferential, from 10 to 03 o'clock, within 8 inches of joint: YES - S21.3 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Capped23.7 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - H28.5 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - H29.8 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - S29.8 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - S35.5 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - S35.5 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - S36.2 ft. FC - Fracture Circumferential, from 08 to 02 o'clock, within 8 inches of joint: YES - S43 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - H49.6 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H51.3 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - SLIGHT58 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - H58 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES - H72 ft. FC - Fracture Circumferential, from 12 to 01 o'clock, within 8 inches of joint: YES - S72 ft. FC - Fracture Circumferential, from 11 to 12 o'clock, within 8 inches of joint: YES - H72.8 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - H78.9 ft. RFL - Roots Fine Lateral, from 08 to 12 o'clock - 10%78.9 ft. FC - Fracture Circumferential, from 12 to 04 o'clock, within 8 inches of joint: YES - S78.9 ft. TFD - Tap Factory Made Defective, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Active 90% ROOTS81.3 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - H86.6 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - H86.9 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - S86.9 ft. FC - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - S93.8 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - S100.7 ft. MGO - General Observation - 15" VCP100.7 ft. FC - Fracture Circumferential, from 08 to 01 o'clock, within 8 inches of joint: YES - H103 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - S115 ft. FL - Fracture Longitudinal, at 8 TO 04 o'clock, within 8 inches of joint: YES, Start - HAIRLINE AT JOINTS115 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT AT JOINTS115 ft. FL - Fracture Longitudinal, at 08 TO 4 o'clock, within 8 inches of joint: YES, Start - SLIGHT AT JOINTS115 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - HAIRLINE AT JOINTS116.9 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Start - H117 ft. FS - Fracture Spiral, from 01 to 03 o'clock, within 8 inches of joint: YES, Start - HAIRLINE122.6 ft. FS - Fracture Spiral, from 01 to 03 o'clock, within 8 inches of joint: YES, Finish - H122.6 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Finish - H124.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open138.5 ft. MWM - Water Mark, 40 %of cross sectional area171 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped220.8 ft. TFD - Tap Factory Made Defective, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open-50% ROOTS269 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped343 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Capped349.4 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 40% SLIGHT349.4 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 40% HAIRLINE349.4 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES, Finish - 20% SLIGHT349.4 ft. FL - Fracture Longitudinal, at 04 o'clock, within 8 inches of joint: YES, Finish - 20% HAIRLINE349.8 ft. AMH - Downstream Manhole, Survey Ends - 4:30AM

Observation photos (3)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

    5 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

  • Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Start - H

    116.9 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Start - H

  • Fracture Spiral, from 01 to 03 o'clock, within 8 inches of joint: YES, Start - HAIRLINE

    117 ft. - Fracture Spiral, from 01 to 03 o'clock, within 8 inches of joint: YES, Start - HAIRLINE

Observations (57)

DistanceCodeObservation
349.4FC40% SLIGHT
116.9FLH
58FCH
171TFCCapped
343TFCCapped
35.5FCS
35.5FCS
0AMH3:30AM
86.9FCS
269TFCCapped
0MWL
100.7MGO15" VCP
138.5MWM
15.4FCHAIRLINE
86.6FCH
9.3FCSLIGHT
21.3TFCCapped
9.3FCS
15.4FCS
43FCH
0MGOConn. @ Mh, 9 O' Clock. Active
81.3FCH
122.6FSH
93.8FCS
349.4FC40% HAIRLINE
103FCS
14.5FCS
72FCS
115FLHAIRLINE AT JOINTS
51.3FCSLIGHT
349.4FL20% SLIGHT
115FCSLIGHT AT JOINTS
349.4FL20% HAIRLINE
86.9FCS
29.8FCS
5FMSLIGHT
220.8TFDOpen-50% ROOTS
122.6FLH
58FLH
72FCH
14.5FCS
115FLSLIGHT AT JOINTS
117FSHAIRLINE
78.9RFL10%
28.5FCH
78.9FCS
0MWM
23.7FCH
100.7FCH
78.9TFDActive 90% ROOTS
115FCHAIRLINE AT JOINTS
36.2FCS
49.6FLH
29.8FCS
349.8AMH4:30AM
124.9TFOpen
72.8FCH

Properties (4)

custom_field_three
SPIRAL HAIRLINE JOINT TO JOINT LONGER
custom_field_two
2
customer
LACSD
datetime
2016-09-29T01:49:14-07:00