Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 29, 2016, 07:38 AM
  • 05 0840_05 0162_9292016_013407.mp4

Date
09/29/2016
W/O
0585473
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00457
PipeID
P06070
Time
12:38 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0297
Sewer Name
05 IMPERIAL HIGHWAY EXTENSION TRUNK
City
HAWTHORNE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
09
Purpose
Routine Assessment
Project
20160923MDM_IMPERIAL_HIGHWAY_EXTENSION_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
05 0840
Downstream MH
05 0162
Dir. of Survey
Downstream
Length Surveyed
4.4 ft.
Total Length
4.4 ft.
Structural Index
2
Structural Quick
2300
Structural Rating
6
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
6
Pipe schematic from manhole 05 0840 to 05 0162
MH: 05 0840MH: 05 0162downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:20AM0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active0 ft. MWL - Water Level, 10 %of cross sectional area2.7 ft. FC - Fracture Circumferential, from 06 to 05 o'clock, within 8 inches of joint: YES - H3 ft. FC - Fracture Circumferential, from 02 to 05 o'clock, within 8 inches of joint: YES - S3 ft. FC - Fracture Circumferential, from 07 to 06 o'clock, within 8 inches of joint: YES - H4 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active4.4 ft. AMH - Downstream Manhole, Survey Ends - 1:30AM

Observations (9)

DistanceCodeObservation
3FCS
2.7FCH
4MGOConn. @ Mh, 9 O' Clock. Active
0MWM
0AMH1:20AM
0MGOConn. @ Mh, 9 O' Clock. Active
4.4AMH1:30AM
0MWL
3FCH

Properties (4)

custom_field_three
SLIGHT FRACTURE
custom_field_two
4
customer
LACSD
datetime
2016-09-29T00:38:55-07:00