Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 20, 2016, 08:55 AM
  • 05 0876_05 0875_9202016_021048.mp4

Date
09/20/2016
W/O
0585472
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00457
PipeID
P06107
Time
1:55 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0286
Sewer Name
05 IMPERIAL HIGHWAY EXTENSION TRUNK
City
LENNOX
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
09
Purpose
Routine Assessment
Project
20160919MDM_IMPERIAL_HIGHWAY_EXTENSION_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Upstream MH
05 0876
Downstream MH
05 0875
Dir. of Survey
Downstream
Length Surveyed
371.8 ft.
Total Length
371.8 ft.
Structural Index
3
Structural Quick
3523
Structural Rating
21
O&M Index
3
O&M Quick
3300
O&M Rating
9
Overall Index
3
Overall Quick
Overall Rating
30
Pipe schematic from manhole 05 0876 to 05 0875
MH: 05 0876MH: 05 0875downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active0 ft. MGO - General Observation - Conn. @ Mh, 8 O' Clock. Active0 ft. AMH - Upstream Manhole, Survey Begins - 1:55AM0 ft. MWL - Water Level, 10 %of cross sectional area41.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - HAIRLINE59.3 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - H97.1 ft. MWM - Water Mark, 40 %of cross sectional area112.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open133.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped134.6 ft. MGO - General Observation - 10" VCP160.1 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open198.5 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - H201.5 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H222.8 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H233 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open237.5 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H267.5 ft. MWM - Water Mark, 30 %of cross sectional area319.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H322.5 ft. MWL - Water Level, 20 %of cross sectional area331.7 ft. FC - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - H335.5 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6", 6" - Capped337.2 ft. DSZ - Deposits Settled Other, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES - METAL CABLE-DVD CLIP #2337.2 ft. DSZ - Deposits Settled Other, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES - METAL CABLE-DVD CLIP #2338.3 ft. DSZ - Deposits Settled Other, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES - METAL CABLE-DVD CLIP #2371.3 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active371.3 ft. MGO - General Observation - Conn. @ Mh, 1 O' Clock. OPEN371.8 ft. AMH - Downstream Manhole, Survey Ends - 2:35AM

Observation photos (5)

  • General Observation - 10" VCP

    134.6 ft. - General Observation - 10" VCP

  • Water Mark, 30 %of cross sectional area

    267.5 ft. - Water Mark, 30 %of cross sectional area

  • Deposits Settled Other,  20 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES - METAL CABLE-DVD CLIP #2

    337.2 ft. - Deposits Settled Other, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES - METAL CABLE-DVD CLIP #2

  • Deposits Settled Other,  20 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES - METAL CABLE-DVD CLIP #2

    337.2 ft. - Deposits Settled Other, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES - METAL CABLE-DVD CLIP #2

  • Deposits Settled Other,  20 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES - METAL CABLE-DVD CLIP #2

    338.3 ft. - Deposits Settled Other, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES - METAL CABLE-DVD CLIP #2

Observations (28)

DistanceCodeObservation
337.2DSZMETAL CABLE-DVD CLIP #2
0MWM
335.5TFCCapped
0MGOConn. @ Mh, 9 O' Clock. Active
371.8AMH2:35AM
201.5FLH
41.1FLHAIRLINE
134.6MGO10" VCP
0MGOConn. @ Mh, 8 O' Clock. Active
322.5MWL
319.4FLH
0AMH1:55AM
97.1MWM
337.2DSZMETAL CABLE-DVD CLIP #2
198.5FCH
267.5MWM
338.3DSZMETAL CABLE-DVD CLIP #2
59.3FCH
331.7FCH
112.3TFOpen
237.5FLH
133.1TFCCapped
371.3MGOConn. @ Mh, 3 O' Clock. Active
371.3MGOConn. @ Mh, 1 O' Clock. OPEN
160.1TBOpen
222.8FLH
233TFOpen
0MWL

Properties (4)

custom_field_three
HAIRLINE FRACTURE
custom_field_two
4
customer
LACSD