02 1621_02 2008_9132016_095355.mp4
0 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO, Start
0 ft. - General Observation - ROACHES INSIDE THE MH.
0 ft. - Upstream Manhole, Survey Begins - 9:52 AM
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start
38.8 ft. - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES
51.3 ft. - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES
54 ft. - Water Level, Sag in pipe, 50 %of cross sectional area, Start
78.5 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN
85.2 ft. - Water Level, Sag in pipe, 50 %of cross sectional area, Finish
92.1 ft. - Material Change, Vitrified clay pipe
92.1 ft. - Joint Separated Large
| Distance | Code | Observation |
|---|---|---|
| 99.8 | MGO | ROACHES INSIDE THE MH. |
| 38.8 | FL | — |
| 85.2 | MWLS | — |
| 0 | SAV | — |
| 92.1 | MMC | — |
| 99.8 | MGO | SLIGHT GREASE THROUGHOUT THE REACH |
| 92.1 | SSS | — |
| 78.5 | FL | POSSIBLY BROKEN |
| 0 | MGO | ROACHES INSIDE THE MH. |
| 0 | AMH | 9:52 AM |
| 100 | AMH | 10:21 AM |
| 92.1 | SAV | — |
| 99.8 | MGO | ACTIVE CONN. INSIDE THE MH. @ 03 O'CLOCK |
| 2 | SSS | — |
| 54 | MWLS | — |
| 0 | MWM | — |
| 51.3 | FC | — |
| 0 | MWL | — |
| 92.1 | JSL | — |