Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 1, 2016, 02:18 PM
  • 29 0519A_29 0519_912016_131814.mp4

Date
09/01/2016
W/O
0591679
Weather
Dry
Operator/Surveyor
DEVIN FRANKLIN
Sewer ID
Z01106
PipeID
P24571
Time
7:18 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7223
Sewer Name
29 19TH STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
03
Purpose
Routine Assessment
Project
20160901DF_19TH_STREET_SEWER
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
29 0519
Downstream MH
29 0519A
Dir. of Survey
Upstream
Length Surveyed
293.7 ft.
Total Length
293.7 ft.
Structural Index
3
Structural Quick
5142
Structural Rating
22
O&M Index
3
O&M Quick
3121
O&M Rating
5
Overall Index
3
Overall Quick
Overall Rating
27
Pipe schematic from manhole 29 0519 to 29 0519A
MH: 29 0519MH: 29 0519Aupstream0 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 8" - CAP HAS MOVED SOIL VISIBLE AT 12 0'CLOCK0 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6" - OPEN0 ft. AMH - Upstream Manhole, Survey Ends - 2:24 PM1.5 ft. FM - Fracture Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES2.4 ft. FM - Fracture Multiple, from 01 to 10 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN3.2 ft. TFD - Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: YES, 6" - OPEN4.5 ft. B - Broken, from 08 to 02 o'clock, within 8 inches of joint: YES - POSSIBLE5.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"23.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN41.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN46.7 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: YES, 6"94.3 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES98.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6"110.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - OPEN114.5 ft. MGO - General Observation - CHIPPING AT JOINT FRON 09 TO 10 0'CLOCK145.4 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES149.5 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: YES, 6" - OPEN152 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 6" - OPEN206.4 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: YES, 6" - OPEN212 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 6" - OPEN222.6 ft. CC - Crack Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES251.2 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: YES, 6"253.8 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: YES, 6" - OPEN270.6 ft. CM - Crack Multiple, from 03 to 09 o'clock, within 8 inches of joint: YES274.2 ft. TBD - Tap Break-In Defective, at 11 o'clock, -, , within 8 inches of joint: YES, 6" - OPEN290.5 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: YES, 6"292.7 ft. MGO - General Observation - ROACHES IN MH292.7 ft. MWL - Water Level, 5 %of cross sectional area292.7 ft. MWM - Water Mark, 10 %of cross sectional area293.7 ft. AMH - Upstream Manhole, Survey Begins - 1:10 PM

Observation photos (8)

  • Tap Break-In Defective, at 11 o'clock, -,  , within 8 inches of joint: YES, 6" - OPEN

    19.5 ft. - Tap Break-In Defective, at 11 o'clock, -, , within 8 inches of joint: YES, 6" - OPEN

  • General Observation - CHIPPING AT JOINT FRON 09 TO 10 0'CLOCK

    179.2 ft. - General Observation - CHIPPING AT JOINT FRON 09 TO 10 0'CLOCK

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    199.4 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    288 ft. - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: YES, 6" - OPEN

    290.5 ft. - Tap Factory Made Defective, at 03 o'clock, -, within 8 inches of joint: YES, 6" - OPEN

  • Fracture Multiple, from 01 to 10 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN

    291.3 ft. - Fracture Multiple, from 01 to 10 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN

  • Fracture Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES

    292.2 ft. - Fracture Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES

  • Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 8" - CAP HAS MOVED SOIL VISIBLE AT 12 0'CLOCK

    293.7 ft. - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 8" - CAP HAS MOVED SOIL VISIBLE AT 12 0'CLOCK

Observations (30)

DistanceCodeObservation
19.5TBDOPEN
39.9TFOPEN
292.2FM
141.7TFOPEN
23.1CM
179.2MGOCHIPPING AT JOINT FRON 09 TO 10 0'CLOCK
183.2TFOPEN
1MGOROACHES IN MH
293.7TFCAP HAS MOVED SOIL VISIBLE AT 12 0'CLOCK
195.2TFC
81.7TFOPEN
3.2TFC
1MWL
252.4TFOPEN
87.3TFOPEN
288TFA
199.4CM
293.7TFOPEN
291.3FMPOSSIBLY BROKEN
144.2TFOPEN
289.2BPOSSIBLE
0AMH1:10 PM
148.3CL
71.1CC
1MWM
42.5TFC
293.7AMH2:24 PM
270.1TFCOPEN
290.5TFDOPEN
247TFC

Properties (2)

customer
LACSD
datetime
2016-09-01T07:18:19-07:00