Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 10, 2016, 04:14 PM
  • 03 0254_03 0253_11102016_084135.mp4

Date
11/10/2016
W/O
0602283
Weather
Dry
Operator/Surveyor
DEVIN FRANKLIN
Sewer ID
Z00385
PipeID
P04856
Time
8:14 AM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7270
Sewer Name
03 MARKET STREET TRUNK
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
07
Purpose
Routine Assessment
Project
20161110DF_MARKET_STREET_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Upstream MH
03 0254
Downstream MH
03 0253
Dir. of Survey
Downstream
Length Surveyed
277.4 ft.
Total Length
277.4 ft.
Structural Index
3
Structural Quick
3B27
Structural Rating
56
O&M Index
2
O&M Quick
2500
O&M Rating
10
Overall Index
3
Overall Quick
Overall Rating
66
Pipe schematic from manhole 03 0254 to 03 0253
MH: 03 0254MH: 03 0253downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 8:21 AM0 ft. MGO - General Observation - ROACHES0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 6 O' Clock. Active14.3 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES22.2 ft. CM - Crack Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES27.6 ft. CM - Crack Multiple, from 12 to 01 o'clock, within 8 inches of joint: YES27.6 ft. TFI - Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 1" - OPEN45.8 ft. CM - Crack Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES49.7 ft. CM - Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES54.1 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES54.9 ft. TFI - Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 1" - OPEN65 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES77.5 ft. CM - Crack Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES89.4 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES - POSSIBLE BROKEN PIPE93.9 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES97.6 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES103.1 ft. TFI - Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 1" - OPEN105.1 ft. CM - Crack Multiple, from 02 to 03 o'clock, within 8 inches of joint: YES109 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES116.6 ft. CM - Crack Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES121.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES124.6 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES133.5 ft. CM - Crack Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES146.9 ft. TFI - Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 1" - ACTIVE152.9 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES153.1 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES157 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES187.4 ft. TFI - Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 1" - OPEN259.1 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES274.6 ft. MGO - General Observation - GREASE THROUGHOUT THE REACH277.4 ft. MGO - General Observation - ROACHES @ MH277.4 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Capped277.4 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active277.4 ft. AMH - Downstream Manhole, Survey Ends - 9:40 AM

Observation photos (25)

  • Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    14.3 ft. - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES

    22.2 ft. - Crack Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 12 to 01 o'clock, within 8 inches of joint: YES

    27.6 ft. - Crack Multiple, from 12 to 01 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 1" - OPEN

    27.6 ft. - Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 1" - OPEN

  • Crack Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

    45.8 ft. - Crack Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES

    49.7 ft. - Crack Multiple, from 11 to 04 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    54.1 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 1" - OPEN

    54.9 ft. - Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 1" - OPEN

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    65 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES

    77.5 ft. - Crack Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES - POSSIBLE BROKEN PIPE

    89.4 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES - POSSIBLE BROKEN PIPE

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    93.9 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    97.6 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 1" - OPEN

    103.1 ft. - Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 1" - OPEN

  • Crack Multiple, from 02 to 03 o'clock, within 8 inches of joint: YES

    105.1 ft. - Crack Multiple, from 02 to 03 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    109 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    121.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    124.6 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES

    133.5 ft. - Crack Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 1" - ACTIVE

    146.9 ft. - Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 1" - ACTIVE

  • Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

    152.9 ft. - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    153.1 ft. - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    157 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 1" - OPEN

    187.4 ft. - Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: YES, 6", 1" - OPEN

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    259.1 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

Observations (36)

DistanceCodeObservation
105.1CM
277.4MGOROACHES @ MH
49.7CM
54.9TFIOPEN
45.8CM
54.1CL
277.4MGOConn. @ Mh, 3 O' Clock. Capped
22.2CM
65CL
121.1CM
146.9TFIACTIVE
124.6CL
77.5CM
0MWM
0AMH8:21 AM
0MGOROACHES
133.5CM
0MWL
259.1CL
103.1TFIOPEN
27.6CM
187.4TFIOPEN
152.9FL
93.9CL
153.1FL
116.6CM
14.3CL
97.6CL
274.6MGOGREASE THROUGHOUT THE REACH
109FL
277.4MGOConn. @ Mh, 3 O' Clock. Active
277.4AMH9:40 AM
27.6TFIOPEN
157FL
0MGOConn. @ Mh, 6 O' Clock. Active
89.4CMPOSSIBLE BROKEN PIPE

Properties (3)

custom_field_two
2
customer
LACSD
datetime
2016-11-10T08:14:58-08:00