Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 10, 2016, 09:11 PM
  • 01 0779_G 0154_11102016_131810.mp4

Date
11/10/2016
W/O
0602673
Weather
Dry
Operator/Surveyor
FRANKLIN
Sewer ID
Z00892
PipeID
P01478
Time
1:11 PM
Certificate
U-415-06024039
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7271
Sewer Name
01 BULLIS ROAD TRUNK
City
COMPTON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
17
Purpose
Routine Assessment
Project
20161110DF_BULLIS_ROAD_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
01 0779
Downstream MH
G 0154
Dir. of Survey
Downstream
Length Surveyed
189.9 ft.
Total Length
189.9 ft.
Structural Index
4
Structural Quick
5443
Structural Rating
41
O&M Index
2
O&M Quick
2500
O&M Rating
10
Overall Index
3
Overall Quick
Overall Rating
51
Pipe schematic from manhole 01 0779 to G 0154
MH: 01 0779MH: G 0154downstream0 ft. AMH - Upstream Manhole, Survey Begins - 1:15 PM0.1 ft. MGO - General Observation - ROACHES0.1 ft. MWM - Water Mark, 10 %of cross sectional area0.1 ft. MWL - Water Level, 5 %of cross sectional area4.5 ft. B - Broken, from 11 to 01 o'clock, within 8 inches of joint: YES, Start8.3 ft. B - Broken, from 11 to 01 o'clock, within 8 inches of joint: YES11.2 ft. MGP - General Photograph - BROKEN PIPE19.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"22.2 ft. TFD - Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: YES, 4" - CAPPED, BROKEN29.2 ft. B - Broken, from 11 to 02 o'clock, within 8 inches of joint: YES38.8 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES41.7 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES41.7 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES44.7 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start50.8 ft. MGP - General Photograph - BROKEN PIPE57.1 ft. MGP - General Photograph - BROKEN PIPE60.4 ft. MGP - General Photograph - BROKEN PIPE68.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 4"70.4 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4" - CAPPED101.2 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN101.7 ft. BVV - Broken Void Visible, at 11 o'clock, within 8 inches of joint: YES109.5 ft. B - Broken, from 01 to 02 o'clock, within 8 inches of joint: YES121.9 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 4"148.8 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4" - CAPPED153.9 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 4"168.4 ft. B - Broken, from 09 to 02 o'clock, within 8 inches of joint: YES170 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4" - CAPPED, BROKEN185 ft. B - Broken, from 11 to 01 o'clock, within 8 inches of joint: YES, Finish185 ft. BSV - Broken Soil Visible, from 07 to 01 o'clock, within 8 inches of joint: YES, Start186.6 ft. MGP - General Photograph - BROKEN PIPE189.2 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish189.2 ft. MGO - General Observation - GREASE THROUGHOUT THE REACH189.2 ft. MGO - General Observation - BROKEN PIPE THROUGHOUT THE REACH189.9 ft. MGO - General Observation - OPEN DROP CONN @ 9 O'CLOCK189.9 ft. AMH - Downstream Manhole, Survey Ends - 2:26 PM/DROPPED MH189.9 ft. BSV - Broken Soil Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish

Observation photos (20)

  • Broken, from 11 to 01 o'clock, within 8 inches of joint: YES, Start

    4.5 ft. - Broken, from 11 to 01 o'clock, within 8 inches of joint: YES, Start

  • Broken, from 11 to 01 o'clock, within 8 inches of joint: YES

    8.3 ft. - Broken, from 11 to 01 o'clock, within 8 inches of joint: YES

  • General Photograph - BROKEN PIPE

    11.2 ft. - General Photograph - BROKEN PIPE

  • Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: YES, 4" - CAPPED, BROKEN

    22.2 ft. - Tap Factory Made Defective, at 11 o'clock, -, within 8 inches of joint: YES, 4" - CAPPED, BROKEN

  • Broken, from 11 to 02 o'clock, within 8 inches of joint: YES

    29.2 ft. - Broken, from 11 to 02 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    38.8 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    41.7 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    41.7 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    44.7 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Photograph - BROKEN PIPE

    50.8 ft. - General Photograph - BROKEN PIPE

  • General Photograph - BROKEN PIPE

    57.1 ft. - General Photograph - BROKEN PIPE

  • General Photograph - BROKEN PIPE

    60.4 ft. - General Photograph - BROKEN PIPE

  • Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4" - CAPPED

    70.4 ft. - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4" - CAPPED

  • Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN

    101.2 ft. - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN

  • Broken Void Visible, at 11 o'clock, within 8 inches of joint: YES

    101.7 ft. - Broken Void Visible, at 11 o'clock, within 8 inches of joint: YES

  • Broken, from 01 to 02 o'clock, within 8 inches of joint: YES

    109.5 ft. - Broken, from 01 to 02 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4" - CAPPED

    148.8 ft. - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4" - CAPPED

  • Broken, from 09 to 02 o'clock, within 8 inches of joint: YES

    168.4 ft. - Broken, from 09 to 02 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4" - CAPPED, BROKEN

    170 ft. - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4" - CAPPED, BROKEN

  • General Photograph - BROKEN PIPE

    186.6 ft. - General Photograph - BROKEN PIPE

Observations (36)

DistanceCodeObservation
29.2B
68.4TFC
60.4MGPBROKEN PIPE
41.7CL
168.4B
121.9TFC
4.5B
148.8TFDCAPPED
11.2MGPBROKEN PIPE
8.3B
189.9MGOOPEN DROP CONN @ 9 O'CLOCK
0.1MGOROACHES
41.7CL
185B
185BSV
186.6MGPBROKEN PIPE
189.2CM
0.1MWM
170TFDCAPPED, BROKEN
189.2MGOGREASE THROUGHOUT THE REACH
189.9AMH2:26 PM/DROPPED MH
101.2TFDOPEN
189.2MGOBROKEN PIPE THROUGHOUT THE REACH
101.7BVV
189.9BSV
38.8CL
44.7CM
22.2TFDCAPPED, BROKEN
70.4TFDCAPPED
50.8MGPBROKEN PIPE
109.5B
19.2TFC
0.1MWL
0AMH1:15 PM
153.9TBA
57.1MGPBROKEN PIPE

Properties (3)

custom_field_two
1
customer
LACSD
datetime
2016-11-10T13:11:21-08:00