Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 30, 2016, 07:19 AM
  • 19 0256_19 0255_8302016_012447.mp4

Date
08/30/2016
W/O
0585465
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00728
PipeID
P15226
Time
12:19 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0260
Sewer Name
19 STUDEBAKER ROAD TRUNK
City
CERRITOS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
01
Purpose
Routine Assessment
Project
20160829MDM_STUDEBAKER_ROAD_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
19 0256
Downstream MH
19 0255
Dir. of Survey
Downstream
Length Surveyed
251 ft.
Total Length
251 ft.
Structural Index
2
Structural Quick
3122
Structural Rating
7
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
9
Pipe schematic from manhole 19 0256 to 19 0255
MH: 19 0256MH: 19 0255downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:20AM4.1 ft. FC - Fracture Circumferential, from 08 to 05 o'clock, within 8 inches of joint: YES - HAIRLINE12.4 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES - HAIRLINE39.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped63.3 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Active91.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open131.9 ft. MGO - General Observation - 15" VCP144.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped149.8 ft. MWM - Water Mark, 20 %of cross sectional area158.7 ft. DAGS - Deposits Attached Grease, 3 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO195.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open247.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6" - Capped249.6 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: NO - HAIRLINE251 ft. AMH - Downstream Manhole, Survey Ends - 1:45AM

Observation photos (1)

  • General Observation - 15" VCP

    131.9 ft. - General Observation - 15" VCP

Observations (16)

DistanceCodeObservation
158.7DAGS
149.8MWM
249.6FCHAIRLINE
0MWL
91.3TFOpen
195.5TFOpen
4.1FCHAIRLINE
144.1TFCCapped
39.6TFCCapped
247.6TFCCapped
131.9MGO15" VCP
63.3TBActive
0MWM
0AMH1:20AM
12.4FLHAIRLINE
251AMH1:45AM

Properties (4)

custom_field_three
FEW HAIRINES
custom_field_two
4
customer
LACSD
datetime
2016-08-30T00:19:03-07:00