Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 27, 2016, 01:56 PM
  • 19 0228_19 0227_8272016_073049.mp4

Date
08/27/2016
W/O
0585415
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00729
PipeID
P15197
Time
6:56 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
HO258
Sewer Name
19 WEST ARTESIA TRUNK
City
CERRITOS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
01
Purpose
Routine Assessment
Project
20160827MDM_WEST_ARTESIA_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
19 0228
Downstream MH
19 0227
Dir. of Survey
Downstream
Length Surveyed
284.3 ft.
Total Length
284.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
4
Pipe schematic from manhole 19 0228 to 19 0227
MH: 19 0228MH: 19 0227downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active0 ft. AMH - Upstream Manhole, Survey Begins - 7:30AM0 ft. MWL - Water Level, 10 %of cross sectional area2.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 04 o'clock, , within 8 inches of joint: NO19.2 ft. MGO - General Observation - 12" VCP90.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped92.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped131.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped190.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped194.5 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open204.3 ft. MWM - Water Mark, 30 %of cross sectional area233.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open272 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped278.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES284.3 ft. AMH - Downstream Manhole, Survey Ends - 7:50AM

Observation photos (1)

  • General Observation - 12" VCP

    19.2 ft. - General Observation - 12" VCP

Observations (16)

DistanceCodeObservation
0MWM
92.9TFCCapped
0MGOConn. @ Mh, 9 O' Clock. Active
233.6TFOpen
194.5TBOpen
190.1TFCCapped
0AMH7:30AM
272TFCCapped
90.2TFCCapped
278.4DAGS
204.3MWM
0MWL
19.2MGO12" VCP
2.8DAGS
284.3AMH7:50AM
131.2TFCCapped

Properties (3)

custom_field_two
4
customer
LACSD
datetime
2016-08-27T06:56:11-07:00