- Date
- 08/25/2016
- W/O
- 0585474
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00767
- PipeID
- P26534
- Time
- 1:14 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H0254
- Sewer Name
- 21 FIRST ST TR, SECT 1A & CONNS TO 1ST ST TR SYSTM
- City
- POMONA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 21
- Page No.
- 14
- Purpose
- Routine Assessment
- Project
- 20160825MDM_FRIST_ST_TR_SECT_1A_CONNS_TO_ST_TR_SYSTM
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 24 in.
- Upstream MH
- 21 0651B
- Downstream MH
- 21 0652
- Dir. of Survey
- Upstream
- Length Surveyed
- 214.9 ft.
- Total Length
- 214.9 ft.
- Structural Index
- 2
- Structural Quick
- 2200
- Structural Rating
- 4
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 4
Pipe schematic from manhole 21 0651B to 21 0652 Observation photos (4)

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING LAITANCE COAT UNDER MAG COAT

2 ft. - General Observation - MAG COAT 95% START 8:00 TO 4:00

86.3 ft. - General Observation - MAG COAT 100%

142.2 ft. - Surface Spalling, from 01 to 02 o'clock, within 8 inches of joint: NO - PEELING LAITANCE COAT