08 0471_08 0470_8132016_011209.mp4
2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE
2 ft. - General Observation - MISSING TILES 100% START 9:00 TO 3:00
2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR -AREAS MISSING TILES
2 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - LONG REBAR AREAS MISSING TILES SPORATIC
9.7 ft. - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: NO - CIRCUM-MISSING REBAR
24.3 ft. - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: YES - CIRCUM REBAR SEPERATED FROM PIPE
31.6 ft. - General Observation - 5%MISSING TILES
43.4 ft. - General Observation - 10% MISSING TILES
60.5 ft. - General Observation - MISSING TILES 10% START
102.5 ft. - General Observation - 100% MISSING TILES
107.4 ft. - Surface Reinforcement Corroded, from 01 to 03 o'clock, within 8 inches of joint: NO - CORROED MISSING REBAR
112.1 ft. - General Observation - MISSING TILES 100%
125.9 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO
135.8 ft. - General Observation - MISSING TILES 5%
165.5 ft. - Surface Reinforcement Corroded, at 12 o'clock, within 8 inches of joint: NO - LONG REBAR
174.5 ft. - General Observation - FEW TILES IN PLACE
189.7 ft. - General Observation - FEW TILES IN PLACE
204.2 ft. - General Observation - FEW TILES IN PLACE
230.8 ft. - General Observation - MISSING TILES 100%
260.9 ft. - General Observation - MISSING TILES 5%
280.7 ft. - General Observation - TILES 100% IN PLACE
289.4 ft. - General Observation - MISSINGT TILES 5% START
315.2 ft. - General Observation - MISSING TILES 70%
401.2 ft. - General Observation - MISSING TILES 80%
414 ft. - General Observation - MISSING TILES 50% START
434.3 ft. - General Observation - MISSING TILES 100% START
445.7 ft. - General Observation - MISSING TILES 605 START
452.5 ft. - General Observation - MISSING TILES 5%
457.7 ft. - General Observation - MISSINGTILES 100%START
463.1 ft. - General Observation - TILES 100% IN PLACE
| Distance | Code | Observation |
|---|---|---|
| 165.5 | SRC | LONG REBAR |
| 470 | SRC | LONG REBAR SPORATIC |
| 135.8 | MGO | MISSING TILES 5% |
| 31.6 | MGO | 5%MISSING TILES |
| 125.9 | SRC | — |
| 315.2 | MGO | MISSING TILES 70% |
| 2 | SAM | SEVERE |
| 280.7 | MGO | TILES 100% IN PLACE |
| 112.1 | MGO | MISSING TILES 100% |
| 260.9 | MGO | MISSING TILES 5% |
| 2 | MGO | MISSING TILES 100% START 9:00 TO 3:00 |
| 60.5 | MGO | MISSING TILES 10% START |
| 470 | SAM | SEVERE AGG |
| 470.7 | AMH | 2:00AM |
| 463.1 | MGO | MISSING TILES 100% FINISH |
| 2 | SRC | CIRCUM REBAR -AREAS MISSING TILES |
| 43.4 | MGO | 10% MISSING TILES |
| 189.7 | MGO | FEW TILES IN PLACE |
| 107.4 | SRC | CORROED MISSING REBAR |
| 414 | MGO | MISSING TILES 50% START |
| 60.5 | MGO | MISSING TILES 100% FINISH |
| 230.8 | MGO | MISSING TILES 100% |
| 0 | AMH | 12:50AM |
| 204.2 | MGO | FEW TILES IN PLACE |
| 0 | MWM | — |
| 102.5 | MGO | 100% MISSING TILES |
| 457.7 | MGO | MISSINGTILES 100%START |
| 470 | SRC | CIRCUM REBAR |
| 0 | MWL | — |
| 463.1 | MGO | TILES 100% IN PLACE |
| 401.2 | MGO | MISSING TILES 80% |
| 24.3 | SRC | CIRCUM REBAR SEPERATED FROM PIPE |
| 470 | MGO | Conn. @ Mh, 9 O' Clock. Active |
| 9.7 | SRC | CIRCUM-MISSING REBAR |
| 452.5 | MGO | MISSING TILES 5% |
| 470 | MGO | Conn. @ Mh, 9 O' Clock. Active |
| 434.3 | MGO | MISSING TILES 100% START |
| 445.7 | MGO | MISSING TILES 605 START |
| 289.4 | MGO | MISSINGT TILES 5% START |
| 174.5 | MGO | FEW TILES IN PLACE |
| 2 | SRC | LONG REBAR AREAS MISSING TILES SPORATIC |