Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 9, 2016, 07:50 AM
  • 29 0480_29 0479_892016_010738.mp4

Date
08/09/2016
W/O
0579988
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00789
PipeID
P24526
Time
12:50 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0226
Sewer Name
29 CHERRY AVENUE TRUNK
City
SIGNAL HILL
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
01
Purpose
Routine Assessment
Project
20160805MDM_CHERRY_AVENUE_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
29 0480
Downstream MH
29 0479
Dir. of Survey
Downstream
Length Surveyed
315.5 ft.
Total Length
315.5 ft.
Structural Index
2
Structural Quick
3A2D
Structural Rating
81
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
81
Pipe schematic from manhole 29 0480 to 29 0479
MH: 29 0480MH: 29 0479downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. OPEN0 ft. AMH - Upstream Manhole, Survey Begins - 12:50AM0 ft. MWL - Water Level, 5 %of cross sectional area6 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SLIGHT8 ft. MGO - General Observation - 8" VCP17.8 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - HAIRLINE24.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SLIGHT48.7 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SL51.9 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - HAIRLINE55.3 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - SL56 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped71.7 ft. FC - Fracture Circumferential, from 11 to 12 o'clock, within 8 inches of joint: YES - SL71.7 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - SL75 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SL85.2 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - H88.6 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL103.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open112 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SLIGHT115.1 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H125.4 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - SLIGHT142.6 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - SL145.7 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - SL153.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped154.3 ft. MGO - General Observation - TRACTOR WHEELES GETTING IN CONN. A PROBLEM155.3 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - SLIGHT161.6 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - H196.2 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - SL203.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H203.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open219.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H226 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - SL226 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - SL232.9 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - SL236.3 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H249.9 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - H253.5 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - H253.5 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - SL254.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped255.9 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL259.4 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H259.4 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - H266.3 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H304 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H304.6 ft. TFB - Tap Factory Made Abandoned, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open313.6 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - SLIGHT313.6 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL315.5 ft. AMH - Downstream Manhole, Survey Ends - 1:55AM

Observation photos (2)

  • General Observation - 8" VCP

    8 ft. - General Observation - 8" VCP

  • General Observation - TRACTOR WHEELES GETTING IN CONN. A  PROBLEM

    154.3 ft. - General Observation - TRACTOR WHEELES GETTING IN CONN. A PROBLEM

Observations (48)

DistanceCodeObservation
236.3FCH
0MWM
203.9TFOpen
304.6TFBOpen
259.4FLH
313.6FCSLIGHT
266.3FLH
304FCH
196.2FCSL
48.7FLSL
315.5AMH1:55AM
0MGOConn. @ Mh, 3 O' Clock. OPEN
0AMH12:50AM
85.2FCH
6FCSLIGHT
51.9FLHAIRLINE
56TFCCapped
55.3FCSL
145.7FCSL
24.6FLSLIGHT
219.1FLH
112FLSLIGHT
125.4FCSLIGHT
253.5FCH
249.9FCH
103.5TFOpen
203.1FLH
259.4FCH
88.6FCSL
255.9FCSL
115.1FCH
154.3MGOTRACTOR WHEELES GETTING IN CONN. A PROBLEM
161.6FCH
313.6FCSL
142.6FCSL
254.2TFCCapped
8MGO8" VCP
226FLSL
253.5FCSL
153.5TFCCapped
155.3FCSLIGHT
75FLSL
71.7FCSL
232.9FCSL
17.8FCHAIRLINE
0MWL
226FCSL
71.7FLSL

Properties (4)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2016-08-09T00:50:00-07:00