- Date
- 07/29/2016
- W/O
- 0579970
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00733
- PipeID
- P15236
- Time
- 12:45 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H0210
- Sewer Name
- 19 219TH STREET TRUNK
- City
- HAWAIIAN GARDENS
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 19
- Page No.
- 06
- Purpose
- Routine Assessment
- Project
- 20160727MDM_219TH_STREET_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Upstream MH
- 19 0265
- Downstream MH
- 19 0266
- Dir. of Survey
- Upstream
- Length Surveyed
- 146.6 ft.
- Total Length
- 146.6 ft.
- Structural Index
- 2
- Structural Quick
- 3121
- Structural Rating
- 6
- O&M Index
- 5
- O&M Quick
- 5141
- O&M Rating
- 9
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 15
Pipe schematic from manhole 19 0265 to 19 0266 Observation photos (6)

12.7 ft. - General Observation - 12"VCP

103.3 ft. - Joint Offset Medium - UNDER FLOW-4:00 TO 8:00

139.2 ft. - Water Level, Sag in pipe, 40 %of cross sectional area

139.2 ft. - Water Mark, 90 %of cross sectional area

142.4 ft. - Joint Offset Large - FULL PIPE OFFSET UNDER FLOW POSSIBLE

146.6 ft. - Upstream Manhole, Survey Ends - 3:45AM-INSPECTION COMPLETED REVERSE INSPECTION