G 0113_G 0086_7122016_022244.mp4
2 ft. - General Observation - MISSING TILES 100% START 9:00 TO 3:00
2 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR CORRODED & MISSING
2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
11.7 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES - BROKEN MISSING REBAR
26.4 ft. - General Observation - 2 ROWS TILES IN PLACE
74 ft. - Surface Reinforcement Corroded, from 09 to 12 o'clock, within 8 inches of joint: NO - BROKEN REBAR
80.2 ft. - General Observation - TILES IN PLACE 80%
97.9 ft. - General Observation - TILES IN PLACE 70% START
176.7 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: YES
197.9 ft. - General Observation - MISSING TILES 20% START
238 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: YES
243.7 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: YES - BROKEN REBAR
248.7 ft. - Surface Reinforcement Corroded, from 12 to 03 o'clock, within 8 inches of joint: NO - BROKEN REBAR
302 ft. - Surface Reinforcement Corroded, from 09 to 03 o'clock, within 8 inches of joint: NO - BROKEN MISSING REBAR LONG & CIRCUM
| Distance | Code | Observation |
|---|---|---|
| 0 | MWM | — |
| 80.2 | MGO | TILES IN PLACE 80% |
| 126.8 | MGO | TILES IN PLACE 70% FINISH |
| 243.7 | SRC | BROKEN REBAR |
| 2 | MGO | MISSING TILES 100% START 9:00 TO 3:00 |
| 74 | SRC | BROKEN REBAR |
| 212.9 | MGO | MISSING TILES 20% FINISH |
| 322.7 | AMH | 2:35AM |
| 322.3 | MGO | Conn. @ Mh, 3 O' Clock. Active LARGE INCOMING |
| 197.9 | MGO | MISSING TILES 20% START |
| 2 | SRC | LONG & CIRCUM REBAR CORRODED & MISSING |
| 11.7 | SRC | BROKEN MISSING REBAR |
| 322.3 | SRC | BROKEN MISSING LONG & CIRCUM REBAR |
| 298.4 | MGO | 2 ROWS TILES IN PLACE |
| 238 | SRC | — |
| 26.4 | MGO | 2 ROWS TILES IN PLACE |
| 248.7 | SRC | BROKEN REBAR |
| 322.3 | MGO | MISSING TILES 100% FINISH |
| 322.3 | SAM | SEVERE AGG |
| 0 | MWL | — |
| 97.9 | MGO | TILES IN PLACE 70% START |
| 176.7 | SRV | — |
| 0 | AMH | 2:00AM |
| 0 | MGO | Conn. @ Mh, 9 O' Clock. Active |
| 302 | SRC | BROKEN MISSING REBAR LONG & CIRCUM |
| 0 | MGO | Conn. @ Mh, 3 O' Clock. Active |
| 2 | SAM | SEVERE AGG |
| 280.8 | MGO | 2 ROWS TLIES IN PLACE |