- Date
- 07/09/2016
- W/O
- 0580099
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z01180
- PipeID
- P00843
- Time
- 1:10 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- HO179
- Sewer Name
- G JOINT OUTFALL G - UNIT 8
- City
- COMPTON
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 16
- Purpose
- Capital Improvement Program Assesment
- Project
- 20160709MDM_JOINT_OUTFALL_G_UNIT_8
- Material
- RCP-CTL
- Shape
- Circular
- Height
- 36 in.
- Upstream MH
- G 0162
- Downstream MH
- G 0161
- Dir. of Survey
- Downstream
- Length Surveyed
- 437.8 ft.
- Total Length
- 437.8 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 3
- O&M Quick
- 3121
- O&M Rating
- 5
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 5
Pipe schematic from manhole G 0162 to G 0161 Observation photos (8)

2 ft. - General Observation - MAG COAT 70% START 8:00 TO 4:00

2 ft. - General Observation - TILES 100% IN PLACE

33.4 ft. - General Observation - MAG COAT 90% START

41.9 ft. - General Photograph

139.2 ft. - General Observation - MAG COAT 80% START

153.3 ft. - General Observation - UNUSAL GLOWING SEWAGE

312.5 ft. - General Observation - MAG COAT 90% START

433.8 ft. - Deposits Attached Grease, 20 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: NO - AT MH OPENIN UPSTREAM