Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 7, 2016, 07:29 AM
  • 19 0094_19 0093_772016_005041.mp4

Date
07/07/2016
W/O
0574205
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00722
PipeID
P15286
Time
12:29 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0176
Sewer Name
19 EAST ARTESIA TRUNK, SECTS 1,2,3,&5
City
HAWAIIAN GARDENS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
07
Purpose
Capital Improvement Program Assesment
Project
20160707MDM_EAST_ARTESIA_TRUNK_SECTS_1_2_3_5
Material
Reinforced Concrete Pipe
Shape
Circular
Height
21 in.
Upstream MH
19 0094
Downstream MH
19 0093
Dir. of Survey
Downstream
Length Surveyed
437.6 ft.
Total Length
437.6 ft.
Structural Index
3
Structural Quick
5241
Structural Rating
40
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
44
Pipe schematic from manhole 19 0094 to 19 0093
MH: 19 0094MH: 19 0093downstream0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. STUB0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 12:30AM2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE6 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR6 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG6 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR12.5 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG12.5 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REBAR12.5 ft. MGO - General Observation - MAG COAT 70% START 9:00 TO 3:0016.9 ft. SSS - Surface Spalling, from 10 to 11 o'clock, within 8 inches of joint: NO - PEELING CONCRETE25.2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE25.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish25.2 ft. MWM - Water Mark, 50 %of cross sectional area32 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES - PEELING CONCRETE53.9 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 6" - Active57.1 ft. MWM - Water Mark, 20 %of cross sectional area57.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE57.1 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish57.1 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 6" - Open66.3 ft. SAV - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC66.3 ft. SSS - Surface Spalling, from 02 to 03 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE72.6 ft. MGO - General Observation - MAG COAT 70% START 8:00 TO 4:0084.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC112.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped163 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Active239.7 ft. MWM - Water Mark, 40 %of cross sectional area239.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open256.6 ft. SSS - Surface Spalling, from 11 to 01 o'clock, within 8 inches of joint: NO - PEELING CONCRETE269.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Active281 ft. SAV - Surface Aggregate Visible, from 09 to 10 o'clock, within 8 inches of joint: NO - SEVERE AGG288.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped308.2 ft. MGO - General Observation - MAG COAT 90% START 9:00 TO 4:00331.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Active386.7 ft. SAV - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG437 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE437 ft. MGO - General Observation - MAG COAT 90% FINISH437 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG SPORATIC437.6 ft. AMH - Downstream Manhole, Survey Ends - 1:30AM

Observation photos (17)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR

    6 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES - LONG CIRCUM REBAR

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    6 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

    6 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

  • General Observation - MAG COAT 70% START 9:00 TO 3:00

    12.5 ft. - General Observation - MAG COAT 70% START 9:00 TO 3:00

  • Surface Spalling, from 10 to 11 o'clock, within 8 inches of joint: NO - PEELING CONCRETE

    16.9 ft. - Surface Spalling, from 10 to 11 o'clock, within 8 inches of joint: NO - PEELING CONCRETE

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    25.2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES - PEELING CONCRETE

    32 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES - PEELING CONCRETE

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    57.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC

    66.3 ft. - Surface Aggregate Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC

  • Surface Spalling, from 02 to 03 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE

    66.3 ft. - Surface Spalling, from 02 to 03 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE

  • General Observation - MAG COAT 70% START 8:00 TO 4:00

    72.6 ft. - General Observation - MAG COAT 70% START 8:00 TO 4:00

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC

    84.5 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC

  • Surface Spalling, from 11 to 01 o'clock, within 8 inches of joint: NO - PEELING CONCRETE

    256.6 ft. - Surface Spalling, from 11 to 01 o'clock, within 8 inches of joint: NO - PEELING CONCRETE

  • Surface Aggregate Visible, from 09 to 10 o'clock, within 8 inches of joint: NO - SEVERE AGG

    281 ft. - Surface Aggregate Visible, from 09 to 10 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • General Observation - MAG COAT 90% START 9:00 TO 4:00

    308.2 ft. - General Observation - MAG COAT 90% START 9:00 TO 4:00

  • Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG

    386.7 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG

Observations (41)

DistanceCodeObservation
12.5SAMSEVERE AGG
0MGOConn. @ Mh, 3 O' Clock. Active
25.2SSSBLISTERING PEELING CONCRETE
437SSSBLISTERING PEELING CONCRETE
0MGOConn. @ Mh, 9 O' Clock. STUB
6SRCLONG CIRCUM REBAR
57.1MWM
0MWL
25.2SSS
239.7MWM
256.6SSSPEELING CONCRETE
2SSSBLISTERING PEELING CONCRETE
66.3SAVSEVERE AGG SPORATIC
0MWM
16.9SSSPEELING CONCRETE
72.6MGOMAG COAT 70% START 8:00 TO 4:00
239.7TFOpen
66.3SSSBLISTERING CONCRETE
331.7TFActive
84.5SAVSEVERE AGG SPORATIC
0AMH12:30AM
57.1SSSBLISTERING PEELING CONCRETE
12.5SRCLONG CIRCUM REBAR
12.5MGOMAG COAT 70% START 9:00 TO 3:00
57.1SSS
6SAMSEVERE AGG
112.8TFCCapped
25.2MWM
53.9TFActive
32SSSPEELING CONCRETE
288.1TFCapped
281SAVSEVERE AGG
57.1TFOpen
6SRCLONG CIRCUM REBAR
386.7SAVSEVERE AGG
308.2MGOMAG COAT 90% START 9:00 TO 4:00
437MGOMAG COAT 90% FINISH
163TFActive
269.3TFActive
437.6AMH1:30AM
437SAVSEVERE AGG SPORATIC

Properties (4)

custom_field_three
CORRODED LONG CIRCUM REBAR-70% MAG COAT
custom_field_two
2
customer
LACSD
datetime
2016-07-07T00:29:30-07:00