- Date
- 07/01/2016
- W/O
- 0574430
- Weather
- Dry
- Operator/Surveyor
- MIRANDA
- Sewer ID
- Z00339
- PipeID
- P21583
- Time
- 8:17 AM
- Certificate
- U-1014-06022542
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G7165
- Sewer Name
- A JOINT OUTFALL A - UNIT 8
- City
- LONG BEACH
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 03
- Page No.
- 04
- Purpose
- Capital Improvement Program Assesment
- Project
- 20160701AM_JOINT_OUTFALL_A_UNIT_8
- Material
- RCP-CTL
- Shape
- Circular
- Height
- 33 in.
- Upstream MH
- A 1098
- Downstream MH
- A 0100
- Dir. of Survey
- Upstream
- Length Surveyed
- 2.1 ft.
- Total Length
- 2.1 ft.
- Structural Index
- 4
- Structural Quick
- 5131
- Structural Rating
- 8
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 8
Pipe schematic from manhole A 1098 to A 0100 Observation photos (6)

0 ft. - Water Level, 30 %of cross sectional area

0 ft. - Upstream Manhole, Survey Begins - 8:30 AM

0 ft. - Water Mark, 35 %of cross sectional area

1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: NO

2 ft. - General Observation - CHIPPING THROUGHOUT

2 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - RIGHT AT THE SOFFIT