Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 30, 2016, 03:39 PM
  • -_29 0528_6302016_090355.mp4

Date
06/30/2016
W/O
0574371
Weather
Dry
Operator/Surveyor
IGNACIO
Sewer ID
Z01106
PipeID
P24582
Time
8:39 AM
Certificate
U-115-06022628
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7164
Sewer Name
29 19TH STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
03
Purpose
Routine Assessment
Project
20160630MI_19TH_STREET_SEWER
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
29 0528
Downstream MH
-
Dir. of Survey
Upstream
Length Surveyed
290 ft.
Total Length
290 ft.
Structural Index
3
Structural Quick
3300
Structural Rating
9
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole 29 0528 to -
MH: 29 0528MH: -upstream0 ft. AMH - Upstream Manhole, Survey Ends - 09:31AM0 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 9"26.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"34.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"73.7 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"88.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - Open94.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"154.7 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 6"157.1 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 6"199.6 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 6" - Open201.3 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: NO, 6"250.9 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: NO, 6"253.3 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"254.9 ft. CM - Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES257.8 ft. CM - Crack Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES276 ft. CM - Crack Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES290 ft. AMH - Downstream Manhole, Survey Begins - 09:00AM290 ft. MWM - Water Mark, 10 %of cross sectional area290 ft. MWL - Water Level, 5 %of cross sectional area

Observations (19)

DistanceCodeObservation
88.7TFA
290AMH09:31AM
0AMH09:00AM
195.2TFA
14CM
132.9TFA
90.4TFOpen
0MWM
263.5TFC
135.3TFA
35.1CM
255.5TFC
216.3TFC
36.7TFC
0MWL
201.3TFOpen
290TFC
39.1TFA
32.2CM

Properties (3)

custom_field_two
4
customer
LACSD
datetime
2016-06-30T08:39:48-07:00