- Date
- 06/28/2016
- W/O
- 0563388
- Weather
- Very Dry
- Operator/Surveyor
- MIRANDA
- Sewer ID
- Z00347
- PipeID
- P10444
- Time
- 9:00 AM
- Certificate
- U-1014-06022542
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- G7162
- Sewer Name
- G JOINT OUTFALL G - UNIT 7
- City
- COMPTON
- Loc. details
- Parking Lot
- Location Code
- G
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 05
- Purpose
- Routine Assessment
- Project
- 20160623AM_JOINT_OUTFALL_G_UNIT_7
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 36 in.
- Upstream MH
- G 0081A
- Downstream MH
- G 0081
- Dir. of Survey
- Downstream
- Length Surveyed
- 210.2 ft.
- Total Length
- 210.2 ft.
- Structural Index
- 3
- Structural Quick
- 3121
- Structural Rating
- 5
- O&M Index
- 4
- O&M Quick
- 4100
- O&M Rating
- 4
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 9
Pipe schematic from manhole G 0081A to G 0081 Observation photos (5)

0 ft. - Upstream Manhole, Survey Begins - 11:15 AM

2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO, Start

2 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: NO, Start

2 ft. - General Observation - 70% MAG COAT FROM 09 TO 03 O'CLOCK, START

47.5 ft. - Water Level, 35 %of cross sectional area