Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 17, 2016, 07:37 AM
Date
06/17/2016
W/O
0577470
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z01125
PipeID
P13537
Time
12:37 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6719
Sewer Name
B JOINT OUTFALL B - UNIT 6H
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
16
Purpose
Routine Assessment
Project
20160617MDM_JOINT_OUTFALL_B_UNIT_6H
Material
CIP
Shape
Circular
Height
18 in.
Upstream MH
B 1217
Downstream MH
B 1216
Dir. of Survey
Downstream
Length Surveyed
163.8 ft.
Total Length
163.8 ft.
Structural Index
3
Structural Quick
523F
Structural Rating
109
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
109
Pipe schematic from manhole B 1217 to B 1216
MH: B 1217MH: B 1216downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:10AM0 ft. MWM - Water Mark, 20 %of cross sectional area2 ft. SCP - Surface Corrosion Metal Pipe, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 25% SUFACE WEAR3.6 ft. SMW - Surface Missing Wall, from 10 to 11 o'clock, within 8 inches of joint: YES - METAL BACKING-24" X 4"3.6 ft. SMW - Surface Missing Wall, from 10 to 11 o'clock, within 8 inches of joint: YES, - METAL BACKING-24" X 4"24.6 ft. MGO - General Observation - DEEP CORRISON 12:0047.6 ft. SCP - Surface Corrosion Metal Pipe, from 08 to 04 o'clock, within 8 inches of joint: YES - 25% SUFACE WEAR66.1 ft. MGP - General Photograph - SURFACE WEAR 12:0092.2 ft. MGO - General Observation - 18" CIP163.4 ft. SCP - Surface Corrosion Metal Pipe, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 25% SUFACE WEAR163.8 ft. AMH - Downstream Manhole, Survey Ends - 1:35AM

Observation photos (7)

  • Surface Corrosion Metal Pipe, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 25% SUFACE WEAR

    2 ft. - Surface Corrosion Metal Pipe, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 25% SUFACE WEAR

  • Surface Missing Wall, from 10 to 11 o'clock, within 8 inches of joint: YES - METAL BACKING-24" X 4"

    3.6 ft. - Surface Missing Wall, from 10 to 11 o'clock, within 8 inches of joint: YES - METAL BACKING-24" X 4"

  • Surface Missing Wall, from 10 to 11 o'clock, within 8 inches of joint: YES, - METAL BACKING-24" X 4"

    3.6 ft. - Surface Missing Wall, from 10 to 11 o'clock, within 8 inches of joint: YES, - METAL BACKING-24" X 4"

  • General Observation - DEEP CORRISON 12:00

    24.6 ft. - General Observation - DEEP CORRISON 12:00

  • Surface Corrosion Metal Pipe, from 08 to 04 o'clock, within 8 inches of joint: YES - 25% SUFACE WEAR

    47.6 ft. - Surface Corrosion Metal Pipe, from 08 to 04 o'clock, within 8 inches of joint: YES - 25% SUFACE WEAR

  • General Photograph - SURFACE WEAR 12:00

    66.1 ft. - General Photograph - SURFACE WEAR 12:00

  • General Observation - 18" CIP

    92.2 ft. - General Observation - 18" CIP

Observations (12)

DistanceCodeObservation
92.2MGO18" CIP
163.4SCP25% SUFACE WEAR
66.1MGPSURFACE WEAR 12:00
3.6SMWMETAL BACKING-24" X 4"
0MWL
24.6MGODEEP CORRISON 12:00
3.6SMWMETAL BACKING-24" X 4"
0AMH1:10AM
0MWM
2SCP25% SUFACE WEAR
163.8AMH1:35AM
47.6SCP25% SUFACE WEAR

Properties (4)

custom_field_three
MISSING WALL WITH METAL BACKING-25%SURFACE WEAR
custom_field_two
1
customer
LACSD
datetime
2016-06-17T00:37:08-07:00